AROYA · Pre-WP5 Firmware Update Readiness · Device & Mesh AuditAROYA · Preparación para la actualización WP5 · Auditoría de dispositivos y malla
Cannabis Haven: 12 Chenell Dr · Facility 3093
Every device bucketed for the scheduled WP4 → WP5 over-the-air push — who receives WP5, who needs bring-up first, who stays on WP4 (not harmed), plus the TEROS One / Climate One trade-in plan.Cada dispositivo clasificado para la actualización WP4 → WP5 por aire — cuáles recibirán WP5, cuáles hay que reactivar antes, cuáles quedan en WP4 (sin daño), más el plan de canje TEROS One / Climate One.
FacilityCannabis Haven: 12 Chenell Dr (ID 3093)StateNew Hampshire (NH) · 12 Chenell Dr, Concord 03301Report date2026-06-10Telemetry window2026-06-10 → 2026-06-11 (last 24 h, continuous)Gateways1 on record · online (H2100002519)Devices38 physical · 74 raw rows (sensors folded)WP4 cohortWP4 fleet → WP5 OTAP via gateway H2100002519 (single-gateway facility)Trade-in pool0 FREE TEROS One Single · 4 paid Climate One candidates
1
Will receive WP5Recibirá WP5
0
Should receive WP5Debería recibir WP5
0
At risk — bring up firstEn riesgo — reactivar antes
0
Likely to miss the pushProbablemente no la reciba
36
Offline — stays on WP4Fuera de línea — queda en WP4
1
Not assessableNo evaluable
38
physical devicesdispositivos físicos
1
WP5-readylistos para WP5
0
bring up firstreactivar primero
36
offline — stay on WP4fuera de línea — quedan en WP4
0
FREE TEROS One trade-incanje TEROS One GRATIS
4
paid Climate One upgrades avail.mejoras Climate One disponibles
Will receive WP5 online & healthyShould receive WP5 minor watchAt risk bring up firstLikely to miss bring up / retireOffline — stays on WP4 not harmedNot assessable gateways
Readiness at a glancePreparación de un vistazo
Readiness by roomPreparación por sala
Fleet compositionComposición de la flota
Mesh backbone:Red troncal: This is a single-gateway facility: gateway H2100002519 is online (last cloud check-in 2026-06-11 UTC, per the portal device register) and the mesh sink is reporting continuously — the uplink path that carries the WP5 push is up. The gateway updates to WP5 and pushes it to every device online at that moment; devices that are offline simply stay on WP4 (unchanged — not harmed). The catch here: only the gateway and sink are communicating today. Every node, repeater and climate station in the register has been silent since 2022–2024, so as it stands the push would update the backbone only and the rest of the fleet would stay on WP4. Any device the site wants on WP5 must be brought online (battery / power / signal) before the scheduled window — or marked for retire / trade-in in the planner below instead of spending bring-up effort. The push is run remotely by AROYA; a site visit is the exception, not the default.
Fleet composition & sensor coverageComposición de flota y cobertura de sensores
Your fleet lists 10 radios as “repeaters”; the serial prefix splits them into 6 range-extender/IO radios and 4 climate stations (H111…) — a repeater-class radio with an Atmos-14 attached. Across the 26 substrate nodes, 0 have a reporting attached sensor, 0 are alive but the sensor isn’t reporting (reseat the probe / check the connector), 26 are dark with the node, and 0 have no sensor paired. Beyond TEROS-12s (17), this fleet also carries Atmos-14 climate sensors, SQ-521 PAR sensors, ES-2 EC/temp sensors and 0 already-upgraded TEROS One probes — attached sensors ride on their host radio for the WP5 push.
FREE TEROS One trade-in pool (retired hosts)Canje TEROS One GRATIS (anfitriones retirados)
Cross-referenced against the retired-device register (portal_api · retired=true, pulled 2026-06-10): sensors whose host puck/radio is flagged retired qualify for a free 1:1 TEROS One Single replacement. This facility's retired register is empty (0 retired devices), so there are 0 free entitlements — every TEROS One / Climate One upgrade here is at the trade-in pricing below.Comparado con el registro de dispositivos retirados: los sensores cuyo anfitrión está retirado califican para un reemplazo TEROS One Single gratis 1:1. El registro de esta instalación está vacío (0 retirados), así que hay 0 canjes gratis — todas las mejoras usan el precio de canje de abajo.
TEROS One & Climate One upgrade plannerPlanificador de mejoras TEROS One y Climate One
Tick the “Upgrade?” box on any sensor — including working ones. TEROS-12 → TEROS One (choose Dual or Single per sensor); Atmos-14 → Climate One. The quote totals exactly from your picks. Pricing is fixed (below).
—
TEROS-12 sensors (→ TEROS One)
—
Atmos-14 sensors (→ Climate One)
0
Ticked for upgrade quote
$0
Total trade-in quote
TEROS One Dual$458$608 MSRP · save $150
TEROS One Single$319$419 MSRP · save $100
Climate One $479$629 MSRP · save $150
$0
TEROS One: 0 single + 0 dual — save $0
$0
Climate One: 0 × $479 — save $0
$0
Total saving vs MSRP ($0) — time-limited
How the WP5 update works & how to prepareCómo funciona la actualización WP5 y cómo prepararse
The gateway updates to WP5 and pushes it to every device that is online and communicating at the scheduled time (the go/no-go is: online, battery ≥ 30%, signal ≥ 50%). Devices that are offline at that moment simply stay on WP4 — they are not harmed, they just don't get the new firmware. The catch is compatibility, not damage: a WP4 device needs a WP4-matched gateway to keep communicating, so the goal is to have as many devices as possible online at the push. The update is run remotely by AROYA; keeping the fleet online is the site's responsibility.
P0Bring as many devices online as possible before the scheduled push. Work the "Offline" and "Likely to miss" lists — replace batteries and shore up signal so each meets online + battery ≥ 30% + signal ≥ 50%. Every device up at push time receives WP5; every device down stays on WP4.
P1Shore up the "At risk" list. Marginal battery/signal devices may drop out around the push window — plan battery swaps and repeater coverage now.
P2Decide what to retire or trade in instead of recovering. For dead/legacy sensors you won't bring back, mark them for a TEROS One / Climate One upgrade in the planner above rather than spending effort reviving them — and claim the free trade-in above first.
P3Confirm the gateway/sink are online in the AROYA app. The gateway carries the push — this is a single-gateway facility, so verify H2100002519 (and the sink) are online before the scheduled update. Both are up as of this report.
After the push, recover any stragglers. Devices that were offline can still be brought current later by reverting a gateway to WP4, bringing them online, re-running, then returning the gateway to WP5 — there's no time limit. Keep the mixed WP4/WP5 window short, though: mixed firmware on one network long-term can cause connectivity issues.
Note: existing WP4 gear keeps working as-is; new AROYA equipment requires WP5, which is the reason to update.
By roomPor sala
Mature 1
10
000091
Mature 2
8
000080
Mature 3
9
000090
Veg Room
4
000040
(infrastructure)
7
100060
By device classPor clase de dispositivo
Substrate node (radio + TEROS-12)
26
0000260
Climate station (radio + Atmos-14)
4
000040
Repeater (range extender)
6
000060
Gateway (mesh → cloud)
1
000001
Sink (mesh root)
1
100000
Every device — readiness, sensor, action & your statusCada dispositivo — preparación, sensor, acción y su estado
Set “Your status” as you work the floor — revived items drop off the active list, and upgrade picks feed the planner above. Your marks sync live across every phone/computer that opens this link. Click Export for a JSON snapshot backup.
Connecting…
0ticked for upgradeTEROS One $0Climate One $0Total quote $0Save $0 vs MSRPResolved 0
Device (operator sees)
Class
Readiness
Room
Sensor
Batt
RSSI
Gaps
Last (h)
Most-likely failure / action
Upgrade?
Your status
Method & scope. One row per physical device; an attached sensor (TEROS-12, Atmos-14, SQ-521 PAR, ES-2, TEROS One)
is folded into the radio it plugs into, and sensor-head serials are masked — locate hardware on the floor by the
H-prefix radio serial only. Class by serial prefix (H111 = climate station, H21x = gateway, H31x/H32x/H33x/H34x = node).
Readiness reflects the WP5 go/no-go — a device receives WP5 only if it's online with battery ≥ 30% and signal ≥ 50% at the
scheduled push; otherwise it stays on WP4 (unharmed) and can be recovered later via a WP4 gateway revert. Telemetry: AROYA
public API, continuous 24 h window (2026-06-10 → 2026-06-11). Flags: battery crit<3.0/warn<3.2 V;
RSSI crit<-95/warn<-85 dBm; link crit<40/warn<60; travel crit>60/warn>30 s; last-seen >48 h = offline.
Priorities: P0 = act before the push, P1 = shore up, P2 = plan/trade-in, P3 = verify only.
This is a device-readiness report — cultivation metrics (dryback in absolute pp, irrigation P0–P3 day-phases)
are covered in the facility's cultivation audits, not here.