AROYA · Pre-WP5 Firmware Update Readiness · Device & Mesh AuditAROYA · Preparación para la actualización WP5 · Auditoría de dispositivos y malla
Cannamatics Page 2 · Facility 3226
2 live WP4 gateways (H2100002167 + H2100002366) awaiting the WP5 push, hosting 48 live units — the primary push targets; 1 gateway already on WP5 (H2100004716); 1 dormant WP4 (H2100002189). Every device bucketed for the scheduled WP4 → WP5 over-the-air push — who receives WP5, who needs bring-up first, who stays on WP4 (not harmed), plus the TEROS One / Climate One trade-in plan.Cada dispositivo clasificado para la actualización WP4 → WP5 por aire — cuáles recibirán WP5, cuáles hay que reactivar antes, cuáles quedan en WP4 (sin daño), más el plan de canje TEROS One / Climate One.
FacilityCannamatics Page 2 (ID 3226)StateCalifornia (CA)Report date2026-06-11Telemetry window2026-06-10 → 2026-06-11 (last 24 h, continuous)Gateways4 on record · 3 online — 2× WP4 (H2100002167 + H2100002366) · 1× WP5 (H2100004716) · 1 dormant WP4 (H2100002189)Devices65 physical · 84 raw rows (sensors folded)WP4 cohort2 live WP4 gateways (H2100002167 + H2100002366, per the WP4 Gateways sheet) awaiting the WP5 OTAP push · H2100004716 already on WP5 · H2100002189 dormant on WP4Trade-in pool0 FREE TEROS One Single · 5 paid Climate One candidates
45
Will receive WP5Recibirá WP5
3
Should receive WP5Debería recibir WP5
0
At risk — bring up firstEn riesgo — reactivar antes
0
Likely to miss the pushProbablemente no la reciba
13
Offline — stays on WP4Fuera de línea — queda en WP4
4
Not assessableNo evaluable
65
physical devicesdispositivos físicos
48
WP5-readylistos para WP5
0
bring up firstreactivar primero
13
offline — stay on WP4fuera de línea — quedan en WP4
0
FREE TEROS One trade-incanje TEROS One GRATIS
5
paid Climate One upgrades avail.mejoras Climate One disponibles
Will receive WP5 online & healthyShould receive WP5 minor watchAt risk bring up firstLikely to miss bring up / retireOffline — stays on WP4 not harmedNot assessable gateways
Readiness at a glancePreparación de un vistazo
Readiness by roomPreparación por sala
Fleet compositionComposición de la flota
Mesh backbone:Red troncal:This facility has 2 live WP4 gateways awaiting the WP5 push, hosting 48 live units; 1 dormant WP4 gateway; and 1 already-WP5 gateway also active. Per the live gateway-firmware audit (ggVersion, pulled 2026-06-11): H2100002167 (“PRK”, room PRK1) and H2100002366 (“TLC”) are both on WP4 and online today — these are the two on the WP4 Gateways sheet and the primary WP5-push targets; schedule them together so the whole fleet moves to WP5 in one window. H2100004716 is already running WP5 and is online (added after the sheet snapshot) — it does not need the push. H2100002189 (“AD”) is a WP4 unit silent since 2024-09-03 — it appears dormant/decommissioned; confirm in the AROYA app before the push. Each WP4 gateway updates to WP5 and pushes it to every device online at that moment; devices that are offline simply stay on WP4 (unchanged — not harmed). The push is run remotely by AROYA; a site visit is the exception, not the default.
Fleet composition & sensor coverageComposición de flota y cobertura de sensores
Your fleet lists 6 radios as “repeaters”; the serial prefix splits them into 1 range-extender/IO radios and 5 climate stations (H111…) — a repeater-class radio with an Atmos-14 attached. Across the 33 substrate nodes, 8 have a reporting attached sensor, 0 are alive but the sensor isn’t reporting (reseat the probe / check the connector), 6 are dark with the node, and 19 have no sensor paired. Beyond TEROS-12s (27), this fleet also carries Atmos-14 climate sensors, SQ-521 PAR sensors and 4 already-upgraded TEROS One probes — attached sensors ride on their host radio for the WP5 push.
FREE TEROS One trade-in pool (retired hosts)Canje TEROS One GRATIS (anfitriones retirados)
Cross-referenced against the retired-device register (portal_api · retired=true, pulled 2026-06-11): sensors whose host puck/radio is flagged retired qualify for a free 1:1 TEROS One Single replacement. This facility's retired register is empty (0 retired devices), so there are 0 free entitlements — every TEROS One / Climate One upgrade here is at the trade-in pricing below.Comparado con el registro de dispositivos retirados: los sensores cuyo anfitrión está retirado califican para un reemplazo TEROS One Single gratis 1:1. El registro de esta instalación está vacío (0 retirados), así que hay 0 canjes gratis — todas las mejoras usan el precio de canje de abajo.
TEROS One & Climate One upgrade plannerPlanificador de mejoras TEROS One y Climate One
Tick the “Upgrade?” box on any sensor — including working ones. TEROS-12 → TEROS One (choose Dual or Single per sensor); Atmos-14 → Climate One. The quote totals exactly from your picks. Pricing is fixed (below).
—
TEROS-12 sensors (→ TEROS One)
—
Atmos-14 sensors (→ Climate One)
0
Ticked for upgrade quote
$0
Total trade-in quote
TEROS One Dual$458$608 MSRP · save $150
TEROS One Single$319$419 MSRP · save $100
Climate One $479$629 MSRP · save $150
$0
TEROS One: 0 single + 0 dual — save $0
$0
Climate One: 0 × $479 — save $0
$0
Total saving vs MSRP ($0) — time-limited
How the WP5 update works & how to prepareCómo funciona la actualización WP5 y cómo prepararse
The gateway updates to WP5 and pushes it to every device that is online and communicating at the scheduled time (the go/no-go is: online, battery ≥ 30%, signal ≥ 50%). Devices that are offline at that moment simply stay on WP4 — they are not harmed, they just don't get the new firmware. The catch is compatibility, not damage: a WP4 device needs a WP4-matched gateway to keep communicating, so the goal is to have as many devices as possible online at the push. The update is run remotely by AROYA; keeping the fleet online is the site's responsibility.
P0Bring as many devices online as possible before the scheduled push. Work the "Offline" and "Likely to miss" lists — replace batteries and shore up signal so each meets online + battery ≥ 30% + signal ≥ 50%. Every device up at push time receives WP5; every device down stays on WP4.
P1Shore up the "At risk" list. Marginal battery/signal devices may drop out around the push window — plan battery swaps and repeater coverage now.
P2Decide what to retire or trade in instead of recovering. For dead/legacy sensors you won't bring back, mark them for a TEROS One / Climate One upgrade in the planner above rather than spending effort reviving them — and claim the free trade-in above first.
P3Confirm the gateways/sinks are online in the AROYA app. The gateways carry the push — verify BOTH WP4 gateways H2100002167 and H2100002366 are online before the scheduled update and schedule them together. H2100004716 is already on WP5 (no push needed); confirm the dormant WP4 unit H2100002189 (silent since 2024-09-03) is decommissioned.
After the push, recover any stragglers. Devices that were offline can still be brought current later by reverting a gateway to WP4, bringing them online, re-running, then returning the gateway to WP5 — there's no time limit. Keep the mixed WP4/WP5 window short, though: mixed firmware on one network long-term can cause connectivity issues.
Note: existing WP4 gear keeps working as-is; new AROYA equipment requires WP5, which is the reason to update.
By roomPor sala
AD1
17
1020032
PRK1
7
200041
TLC-1
13
1300000
TLC-2
13
1210000
TLC-D
1
000001
TLC-V
9
500040
(infrastructure)
5
300020
By device classPor clase de dispositivo
Substrate node (radio + TEROS-12)
33
2230080
Climate station (radio + Atmos-14)
5
400010
Repeater (range extender)
1
000010
Gateway (mesh → cloud)
4
000004
Sink (mesh root)
3
300000
Unpaired sensor
19
1600030
Every device — readiness, sensor, action & your statusCada dispositivo — preparación, sensor, acción y su estado
Set “Your status” as you work the floor — revived items drop off the active list, and upgrade picks feed the planner above. Your marks sync live across every phone/computer that opens this link. Click Export for a JSON snapshot backup.
Connecting…
0ticked for upgradeTEROS One $0Climate One $0Total quote $0Save $0 vs MSRPResolved 0
Device (operator sees)
Class
Readiness
Room
Sensor
Batt
RSSI
Gaps
Last (h)
Most-likely failure / action
Upgrade?
Your status
Method & scope. One row per physical device; an attached sensor (TEROS-12, Atmos-14, SQ-521 PAR, ES-2, TEROS One)
is folded into the radio it plugs into, and sensor-head serials are masked — locate hardware on the floor by the
H-prefix radio serial only. Class by serial prefix (H111 = climate station, H21x = gateway, H31x/H32x/H33x/H34x = node).
Readiness reflects the WP5 go/no-go — a device receives WP5 only if it's online with battery ≥ 30% and signal ≥ 50% at the
scheduled push; otherwise it stays on WP4 (unharmed) and can be recovered later via a WP4 gateway revert. Telemetry: AROYA
public API, continuous 24 h window (2026-06-10 → 2026-06-11). Flags: battery crit<3.0/warn<3.2 V;
RSSI crit<-95/warn<-85 dBm; link crit<40/warn<60; travel crit>60/warn>30 s; last-seen >48 h = offline.
Priorities: P0 = act before the push, P1 = shore up, P2 = plan/trade-in, P3 = verify only.
This is a device-readiness report — cultivation metrics (dryback in absolute pp, irrigation P0–P3 day-phases)
are covered in the facility's cultivation audits, not here.