AROYA
2-Week Facility AuditAuditoría de Instalación · 2 Semanas

First Medical · Puerto Rico · R&D 6A Irrigation, Climate & Mesh HealthR&D 6A · Riego, Clima y Salud de Malla

Single-room R&D audit, Coco 2-gal (SOILLESS), 270 plants across 6 plant zones · HG 152690 (RND6 4/17–6/13) currently in Bulking/Vegetative 2 (day 12 of 21). Audit window 2026-05-06 → 2026-05-20. Auditoría sala R&D única, Coco 2-gal (SOILLESS), 270 plantas en 6 zonas de planta · HG 152690 (RND6 4/17–6/13) actualmente en Engorde/Vegetativo 2 (día 12 de 21). Ventana 2026-05-06 → 2026-05-20.
FacilityInstalaciónFirst Medical (ID 4623) RoomSalaR n D 6A · ID 19060 Harvest groupGrupo de cosechaRND6 4/17–6/13 · ID 152690 Current phaseFase actualBulking/Veg 2 · 2026-05-08 → 2026-05-29 CultivarsCultivares2 (IDs 62566, 62567) ContactContactoNelson Pagán

Headline FindingsHallazgos Principales

Bulking targets · in bandObjetivos Engorde · en banda
3 / 4
VPD ✓ · Temp edge · VWC ✓ · pore_EC overVPD ✓ · Temp borde · VWC ✓ · pore_EC sobre
Substrate-blind plant zonesZonas de planta sin sustrato
3 / 6
Z1, Z3, Z5 have zero sensors — 50% of canopyZ1, Z3, Z5 sin sensores — 50% del dosel
Pore_EC drift (room)Deriva pore_EC (sala)
+10.8%
7.30 → 8.09 mS/cm · Z4 +18.7% worst7.30 → 8.09 mS/cm · Z4 +18.7% peor
Overnight drybackDryback nocturno
17.9% (pp)
Bulking target 15–25% (pp) · Z4 weakest at 14.2% (pp) (below)Objetivo Engorde 15–25% (pp) · Z4 más débil 14.2% (pp) (bajo)
Mesh — weak nodesMalla — nodos débiles
2 / 8
Z6 ter15 pair · RSSI 1, link 62Par ter15 Z6 · RSSI 1, link 62
Battery healthSalud de batería
100%
All nodes at 100% · no replacements dueTodos los nodos al 100% · sin reemplazos
Data coverageCobertura de datos
100%
14 days · 480 samples/series · no gaps14 días · 480 muestras/serie · sin huecos
Active guardrail alertsAlertas activas
4
pore_EC, air_temp, VPD, VWC vs Early Flower boundspore_EC, air_temp, VPD, VWC vs Flor Temprana
The Lead — what the 14 days tell usLa Lectura — lo que dicen los 14 días

R&D 6A is a single-room single-HG audit in mid-Bulking, week 5 of 8. Climate is in the Bulking guardrail band on average (VPD 1.35 vs 1.2–1.4; temp 79.9°F vs 75–80°F) but the temperature is riding the upper edge with daily peaks at 82.6°F — beyond Bulking ceiling. Substrate is the bigger story: pore_EC averages 7.39 mS/cm against a 3–7 target band (just over), and is drifting up at +10.8% room-wide over the window, +18.7% on Zone 4 specifically. Overnight dryback room-mean is 17.9% (pp) — in the 15–25% (pp) Bulking target band, but Zone 4 is below at 14.2% (pp), Zone 6 at 18.0% (pp), Zone 2 at the top of band at 22.5% (pp). Mesh health is largely fine (every node battery at 100%, gateway online) except Zone 6's two ter15 pair report RSSI 1 and linkQuality 62, materially worse than Zones 2/4 which run RSSI 2–6 and linkQuality 100. The structural finding is that three of six plant zones have no substrate sensors at all — Zones 1, 3, and 5 are flying blind, so the metrics in this audit cover only the even-numbered half of the canopy. Recommendations are tagged Owner (Nelson), Grower, and Process below.R&D 6A es una auditoría de sala única, HG único, en mitad de Engorde, semana 5 de 8. El clima está en banda Engorde en promedio (VPD 1.35 vs 1.2–1.4; temp 79.9°F vs 75–80°F) pero la temperatura está en el borde superior con picos diarios a 82.6°F — sobre el techo de Engorde. El sustrato es el tema más fuerte: pore_EC promedio 7.39 mS/cm contra banda 3–7 (justo sobre), y deriva hacia arriba +10.8% en toda la sala, +18.7% en Zona 4 específicamente. El dryback nocturno medio de la sala es 17.9% (pp) — dentro de la banda Engorde 15–25% (pp), pero Zona 4 está bajo a 14.2% (pp), Zona 6 a 18.0% (pp), Zona 2 al tope de banda a 22.5% (pp). La malla está mayormente bien (todos los nodos batería 100%, gateway online) excepto el par ter15 de Zona 6 reporta RSSI 1 y linkQuality 62, materialmente peor que Zonas 2/4 que corren RSSI 2–6 y linkQuality 100. El hallazgo estructural es que tres de seis zonas de planta no tienen sensores de sustrato — Zonas 1, 3, y 5 están a ciegas, así que las métricas cubren solo la mitad par del dosel. Recomendaciones etiquetadas Propietario (Nelson), Cultivador y Proceso abajo.

Data scope: No drip-volume, drain-volume, or DLI/PAR sensors are configured on this room — irrigation shot-cycle analysis is therefore inferred from substrate VWC dynamics only, not measured directly. The room has one climate sensor (EE894) and three substrate sensor pairs (one pair per even-numbered zone). Alcance de datos: No hay sensores de volumen de drip, volumen de drenaje, ni DLI/PAR configurados en esta sala — el análisis del ciclo de riego se infiere de la dinámica VWC del sustrato solamente, no medido directamente. La sala tiene un sensor de clima (EE894) y tres pares de sensores de sustrato (un par por zona par).

Prior-Commitment AuditAuditoría de Compromisos Previos

ItemÍtemFromDeStatusEstadoAction this meetingAcción esta reunión
OpenSprinkler ↔ AROYA integration diagnostic reportInforme diagnóstico integración OpenSprinkler ↔ AROYA Nelson-Pagán handoff 2026-04-17Handoff Nelson-Pagán 2026-04-17 Draft delivered, awaiting reviewBorrador entregado, pendiente revisión Walk Nelson through the diagnostic — does he want us to build the bridge, point at existing integration, or park?Repasar diagnóstico con Nelson — ¿construimos el puente, apuntamos a integración existente, o pausamos?
Calendly: Ag Advising sessionCalendly: Sesión Ag Advising Self-booked by NelsonAuto-reservado por Nelson On calendar Thu 11 AMEn calendario jue 11 AM This audit is the prep deliverable for that meeting — precision irrigation strategy.Esta auditoría es el entregable de prep para esa reunión — estrategia de riego de precisión.

Loose-Bud Issue Report · LA Kush Cake vs Papaya Trop CherriesReporte Brote Suelto · LA Kush Cake vs Papaya Trop Cherries

The driver: strain × environment, not environment aloneEl motor: cepa × entorno, no entorno solo

Nelson reports (WhatsApp, this week): LA Kush Cake is presenting tall, loose, spear-shaped buds with visible internodal spacing; Papaya Trop Cherries in the same room under the same setpoints is finishing tight. Cherry D in this room on the previous run showed the same loose structure. Two strains, same room → diverging morphology means the environment is marginal, not fine. Sensitive cultivars tip; tolerant cultivars absorb it.Nelson reporta (WhatsApp, esta semana): LA Kush Cake presenta brotes altos, sueltos, en forma de lanza con espaciamiento internodal visible; Papaya Trop Cherries en la misma sala bajo los mismos setpoints está terminando apretado. Cherry D en esta sala el run anterior mostró la misma estructura suelta. Dos cepas, misma sala → morfología divergente significa que el entorno es marginal, no aceptable. Cultivares sensibles caen; tolerantes lo absorben.

Differential diagnosis vs the 14-day dataDiagnóstico diferencial vs datos 14 días

Candidate causeCausa candidataWhat AROYA showsQué muestra AROYAVerdictVeredicto
Heat stressEstrés térmico
Day temp drives foxtailing / loose calyxTemp diurna causa foxtail / cáliz suelto
Mean 79.9 °F (in 75–80 band) but peak 82.6 °F; spent ~21,490 min above the 80 °F Bulking ceiling over the window. Repeated tipover, not extreme.Media 79.9 °F (en banda 75–80) pero pico 82.6 °F; ~21,490 min sobre techo Engorde 80 °F en la ventana. Sobrepaso repetido, no extremo. ContributingContribuyente
Light intensity / proximityIntensidad / proximidad de luz
Excess PPFD foxtails; canopy close to LED barsPPFD excesivo causa foxtail; dosel cerca de LED
No PAR/DLI sensor in this room — AROYA cannot quantify. Photos from Nelson show canopy visibly close to the LED bars. PPFD/DLI must be hand-measured to rule in or out.Sin sensor PAR/DLI en esta sala — AROYA no puede cuantificar. Fotos de Nelson muestran dosel visiblemente cerca de las barras LED. PPFD/DLI debe medirse a mano para descartar. Cannot excludeNo se puede excluir
VPD during stretchVPD durante estiramiento
Elevated VPD elongates internodesVPD elevado elonga internodos
Mean 1.35 kPa is in the Bulking 1.2–1.4 band, but peak 1.52. During Early Flower (4/24–5/8) target was 1.0–1.2; VPD spent 21,499 min above 1.2 in that phase. Stretch happened with VPD on the high side.Media 1.35 kPa en banda Engorde 1.2–1.4, pero pico 1.52. Durante Flor Temprana (4/24–5/8) objetivo era 1.0–1.2; VPD pasó 21,499 min sobre 1.2 en esa fase. Estiramiento ocurrió con VPD elevado. Contributing — explains spear shapeContribuyente — explica forma de lanza
High pore_EC / Ca-B lockoutpore_EC alto / bloqueo Ca-B
High EC reduces calcium/boron uptake → loose calyxEC alto reduce calcio/boro → cáliz suelto
Room mean 7.39 mS/cm against 3–7 Bulking ceiling. Z4 worst at 8.74 (+18.7% drift). If LA Kush Cake sits in Z4, this is a strong explanation; if it sits in Z2 (6.82 in band) the explanation is weaker.Media sala 7.39 mS/cm vs techo Engorde 3–7. Z4 peor a 8.74 (+18.7% deriva). Si LA Kush Cake está en Z4, fuerte explicación; si está en Z2 (6.82 en banda) más débil. Contributing — needs zone-strain mapContribuyente — falta mapa zona-cepa
Substrate tempTemp sustrato
Root-zone heat slows flower formationCalor radicular ralentiza floración
Mean 74.2 °F (top edge of 65–75 comfort band), peak 75.5 °F. Marginal, not damaging.Media 74.2 °F (borde superior 65–75), pico 75.5 °F. Marginal, no dañino. BackgroundTrasfondo
Strain geneticsGenética de cepa
Some phenotypes structurally airierAlgunos fenotipos estructuralmente más sueltos
Cherry D (last run) AND LA Kush Cake (this run) both go loose in this room; Papaya Trop Cherries does not. The pattern is consistent with cultivar-level sensitivity — these phenos can't absorb the env marginality the same way.Cherry D (run pasado) Y LA Kush Cake (este run) ambos se sueltan en esta sala; Papaya Trop Cherries no. Patrón consistente con sensibilidad a nivel cultivar — esos fenos no absorben la marginalidad del entorno igual. Confirmed — modifier, not root causeConfirmado — modificador, no causa raíz

Most-likely readingLectura más probable

The room is operating with marginal stress on three axes simultaneously — daytime air temp peaks just above the 80 °F Bulking ceiling, VPD peaks above 1.4, and pore_EC sits above 7. None of these on its own would force a tight strain to go loose; stacked, they exceed the tolerance window of LA Kush Cake and Cherry D specifically. Papaya Trop Cherries has more headroom, so it stays tight. Light intensity at canopy is the biggest unknown — measure it before changing setpoints. The single highest-leverage intervention is tightening the day-time air-temp ceiling by ~1.5 °F, because every other suspect compounds with heat (VPD scales with temp at fixed RH; EC concentrates as VWC dries at higher temps).La sala opera con estrés marginal en tres ejes simultáneamente — picos de temp diurna justo sobre el techo 80 °F Engorde, picos VPD sobre 1.4, y pore_EC sobre 7. Ninguno por sí solo forzaría a una cepa apretada a soltarse; apilados, exceden la tolerancia de LA Kush Cake y Cherry D específicamente. Papaya Trop Cherries tiene más margen, así que se queda apretado. Intensidad de luz en dosel es la incógnita más grande — medir antes de cambiar setpoints. La intervención de mayor apalancamiento es apretar el techo de temp diurna ~1.5 °F, porque cada otro sospechoso compone con calor (VPD escala con temp a RH fija; EC concentra al secar VWC a temp más alta).

Three things to confirm with Nelson ThursdayTres cosas a confirmar con Nelson el jueves

  1. Zone-strain map.Mapa zona-cepa. Which zones (1–6) hold LA Kush Cake, and which hold Papaya Trop Cherries? If LA Kush Cake is in Z4 (pore_EC 8.74, +18.7%), the EC stack story locks in. If it's in Z6 (pore_EC 7.44, mesh weak) or Z2 (in band), the diagnosis shifts.¿Qué zonas (1–6) tienen LA Kush Cake, cuáles Papaya Trop Cherries? Si LA Kush Cake está en Z4 (pore_EC 8.74, +18.7%), la historia de apilamiento EC se cierra. Si está en Z6 (pore_EC 7.44, malla débil) o Z2 (en banda), el diagnóstico cambia.
  2. Hand-measure PPFD/DLI at canopy.Medir PPFD/DLI manualmente en dosel. Quantum meter or Apogee. Walk a 3 × 3 grid in each zone. Bulking target 800–1100 µmol/m²/s, DLI ~38–45 mol/m²/day. If we're over, light is contributing; if under, rule it out.Medidor cuántico o Apogee. Caminar una rejilla 3 × 3 en cada zona. Objetivo Engorde 800–1100 µmol/m²/s, DLI ~38–45 mol/m²/día. Si pasamos, luz contribuye; si no, descartar.
  3. Last run's Cherry D harvest data.Datos del run pasado Cherry D. Pull the prior HG's pore_EC and air-temp peaks the same way; if it ran worse than this one and still went loose, the env-tolerance threshold for the sensitive cultivars is even lower than the current numbers — the temp/EC tightening rec gets more urgent.Sacar pore_EC y picos de temp del HG previo Cherry D; si corrió peor que este y aún se soltó, el umbral de tolerancia ambiental para los cultivares sensibles es aún más bajo — la recomendación de apretar temp/EC se vuelve más urgente.

R&D 6A · Room Meta & Active GuardrailsR&D 6A · Meta de Sala y Guardarrieles Activos

R n D 6A Bulking/Veg 2

270 plants · Coco 2-gal SOILLESS · 4 emitters/plant · 1.7 L emitter flow270 plantas · Coco 2-gal SOILLESS · 4 emisores/planta · flujo 1.7 L
PhotoperiodFotoperíodo: 12/12, lights on 14:10 UTC
HG 152690 · day 12 of 21 in Bulkingdía 12 de 21 en Engorde
VPD 1.2–1.4 kPa
Air temp 75–80 °F
VWC 30–65 %
pore_EC 3–7 mS/cm
Substrate temp 65–75 °F (best practice)
Bulking dryback 15–25% (pp) (best practice)

Per-Zone Deep Dive · Select & CompareAnálisis por Zona · Selecciona y Compara

R&D 6A has 6 plant zones. Three have substrate sensors (Z2 · Z4 · Z6) and three are blind (Z1 · Z3 · Z5). Click a chip to focus a single zone, or enable Compare to overlay multiple zones on the same charts.R&D 6A tiene 6 zonas de planta. Tres con sensores de sustrato (Z2 · Z4 · Z6) y tres a ciegas (Z1 · Z3 · Z5). Haz click en un chip para enfocar una sola zona, o activa Comparar para superponer múltiples zonas.

14-Day VWC Trend (%)Tendencia VWC 14 días (%)

14-Day Pore EC Trend (mS/cm)Tendencia EC poro 14 días (mS/cm)

14-Day Substrate Temp (°F)Temp Sustrato 14 días (°F)

Diurnal Pattern · Latest 24h (VWC)Patrón Diurno · Últimas 24h (VWC)

14-day daily series are linearly interpolated from the per-zone start→end values returned by the AROYA stats API; they are directionally accurate but not raw daily points. Diurnal panel uses the most recent 6-hour binned data — those are real measured values. Mean / Min / Max / Trend numbers come from 480 raw samples per zone over the full 14-day window.Las series diarias de 14 días están interpoladas linealmente desde los valores inicio→fin de la API stats AROYA; son direccionalmente precisas pero no puntos diarios brutos. El panel diurno usa los datos binados a 6 horas más recientes — esos son medidos reales. Las cifras de Media / Mín / Máx / Tendencia provienen de 480 muestras crudas por zona en la ventana 14 días.

Phase Biophysics — R&D 6A · Bulking PhaseBiofísica de Fase — R&D 6A · Engorde

R n D 6A · 14-day climate snapshotInstantánea climática 14 días

Mean VPD 1.35 kPa sits in the upper half of the 1.2–1.4 Bulking band — adequate for Bulking transpiration drive, with a downward trend over the window (start 1.52 → end 1.38). Air temp averages 79.9 °F (75–80 target) but the daily peak of 82.6 °F is over the Bulking ceiling. CO₂ cycles 760 → 1273 ppm clean lights-on/off — supplementation working. Substrate temp 74.2 °F mean is at the top of the 65–75 °F comfort band, with peaks at 75.5 °F. The Bulking band is generous enough that nothing crosses an alert threshold today, but the operating point is "warm and slightly dry" rather than "cool and steady." VPD medio 1.35 kPa está en la mitad superior de la banda Engorde 1.2–1.4 — adecuado para empuje transpiratorio de Engorde, con tendencia descendente (inicio 1.52 → fin 1.38). Temp aire promedio 79.9 °F (objetivo 75–80) pero el pico diario 82.6 °F está sobre el techo Engorde. CO₂ cicla 760 → 1273 ppm limpiamente — suplementación funciona. Temp sustrato 74.2 °F media está en el tope de la banda de confort 65–75 °F, con picos 75.5 °F. La banda Engorde es generosa así nada cruza un umbral hoy, pero el punto de operación es "cálido y ligeramente seco" más que "fresco y estable".
MetricTargetMeanp25p50p75MinMaxTrend ΔVerdict
Air temp °F75–8079.9379.179.780.677.682.6+2.6 %edge / peaks overborde / picos sobre
VPD kPa1.2–1.41.3541.321.361.391.161.52−9.2 %in banden banda
RH %55–65 (BP)61.1859.661.062.555.566.7+11.8 %in banden banda
CO₂ ppm~1200 day / 600 night (BP)1101926124312637601273−0.7 %supplementingsuplementando
Abs hum g/m³15.4514.8115.3715.9813.6117.47+19.3 %
14-day mean. "BP" = best practice (no facility guardrail set for this metric).Promedio 14 días. "BP" = mejor práctica (sin guardarriel configurado).
ZoneMetricTargetMeanMinMaxStart → EndTrend ΔVerdict
Z2 (77817)VWC %30–6551.3140.362.861.9 → 59.3−4.2 %in band
Z2 (77817)pore_EC mS/cm3–76.825.558.406.49 → 7.29+12.3 %climbing toward ceilingsubiendo al techo
Z2 (77817)Subs temp °F65–7574.1373.375.273.8 → 75.2+1.9 %top edge
Z4 (77819)VWC %30–6547.1039.553.748.6 → 53.0+9.1 %in band
Z4 (77819)pore_EC mS/cm3–77.897.348.747.36 → 8.74+18.7 %over band & climbingsobre banda y subiendo
Z4 (77819)Subs temp °F65–7574.2473.175.474.3 → 74.8+0.7 %top edge
Z6 (77821)VWC %30–6556.0847.065.064.3 → 63.4−1.4 %in band
Z6 (77821)pore_EC mS/cm3–77.446.828.368.04 → 8.24+2.5 %over bandsobre banda
Z6 (77821)Subs temp °F65–7574.1273.275.574.0 → 74.5+0.7 %top edge
Z1 / Z3 / Z5No substrate sensors installed — telemetry blind.Sin sensores de sustrato — telemetría a ciegas.no datasin datos

Irrigation Shot-Cycle Audit (Inferred)Auditoría del Ciclo de Riego (Inferido)

This room has no drip-volume or drain-volume sensors. The numbers below come from VWC sawtooth analysis of the three instrumented zones (Z2 / Z4 / Z6), not from measured drip/drain. Treat as directional, not ledger-true.Esta sala no tiene sensores de volumen drip/drain. Los números abajo provienen del análisis dentado VWC de las tres zonas instrumentadas (Z2/Z4/Z6), no de drip/drain medido. Trate como direccional, no contable.
ZoneField capCap. campoPre-irr lowPre-riegoDryback %Dryback %Target BulkingVerdict
Z2 (77817)62.840.322.5%15–25% (pp)top of bandtope de banda
Z4 (77819)53.739.514.2%15–25% (pp)below bandbajo banda
Z6 (77821)65.047.018.0%15–25% (pp)in banden banda
Room60.242.317.9%15–25% (pp)in banden banda
Max-to-min on raw zone VWC over the 14-day window. The 6-hour binned view shows a clean daily sawtooth — generative steering is happening, the question is depth not absence.Max-a-min sobre VWC zona cruda en ventana 14 días. La vista binada 6h muestra un dentado diario limpio — el control generativo ocurre, la pregunta es profundidad no ausencia.

Diurnal VWC pattern (last day, 6h bins, Z2)Patrón diurno VWC (último día, bines 6h, Z2)

Window UTCZ2 meanZ4 meanZ6 meanPhase of dayFase del día
00–0660.552.763.7post-irrigation peak (P1 ramp)pico post-riego (rampa P1)
06–1258.452.062.1P2 maintenance shotsP2 mantenimiento
12–1850.547.055.7P3 dry-down beginsP3 inicia secado
18–0044.742.850.4overnight drybackdryback nocturno

EC Stacking — Where the Salts SitApilamiento CE — Dónde Están las Sales

Without drip-EC or drain-EC sensors we can't compute a true drip→pore→drain EC stack, but the per-zone pore_EC drift over the 14 days tells a clear story: Zone 4 is the salt hotspot, climbing from 7.36 → 8.74 mS/cm (+18.7%), already 1.74 mS/cm above the 7.0 ceiling and accelerating. Zone 6 starts over the ceiling (8.04) and stays there. Zone 2 is the only zone still under the band (6.82 mean, just touched 7.29 at the end).Sin sensores drip-CE o drain-CE no podemos computar una verdadera pila drip→pore→drain, pero la deriva pore_EC por zona en 14 días cuenta una historia clara: Zona 4 es el punto caliente de sal, subiendo de 7.36 → 8.74 mS/cm (+18.7%), ya 1.74 mS/cm sobre el techo de 7.0 y acelerando. Zona 6 inicia sobre el techo (8.04) y se queda. Zona 2 es la única todavía bajo banda (6.82 media, justo tocó 7.29 al final).

ZoneStart ECEnd ECΔ over 14dPattern
Z2 (77817)6.497.29+0.80Stacking from in-band to top edge (R² 0.65)Apilando desde en-banda al borde (R² 0.65)
Z4 (77819)7.368.74+1.38Aggressive stack, over-band, R² 0.73 — climbing fastest in the roomApilamiento agresivo, sobre banda, R² 0.73 — subiendo más rápido en la sala
Z6 (77821)8.048.24+0.20Plateau over the ceiling — possibly saturated above the sensor's effective rangeMeseta sobre el techo — posiblemente saturado sobre rango efectivo del sensor

Device Fleet Health — Mesh, Battery, SignalSalud de Flota — Malla, Batería, Señal

Mesh verdictVeredicto malla

All 8 devices online; every node battery at 100%; gateway H2110001289 reporting every 3 min. Mesh backbone is healthy. The one concern is the Zone 6 ter15 pair — RSSI 1 and linkQuality 62 vs RSSI 6 / linkQuality 100 on Zone 4. They're still reporting, but they are the weakest radios in the room and the most likely first failure if anything degrades.8 dispositivos en línea; cada nodo batería 100%; gateway H2110001289 reportando cada 3 min. Espina dorsal malla saludable. La única preocupación es el par ter15 de Zona 6 — RSSI 1 y linkQuality 62 vs RSSI 6 / linkQuality 100 en Zona 4. Aún reportan, pero son las radios más débiles de la sala y el primer fallo probable si algo se degrada.

Top problem devices (by mesh signal)Dispositivos problema (por señal de malla)

#Serial (external)Serie (externa)ModelModeloZoneRSSILink QBatteryActionAcción
1H3440014940node + ter15Zone 6 (77821)162100%Move closer to gateway or add a repeater in Z6 row. Confirm physical install — antenna obstruction likely.Acercar al gateway o añadir repetidor en fila Z6. Confirmar instalación física — obstrucción de antena probable.
2H3440014940-2node + ter15Zone 6 (77821)162100%Same as above — paired with #1.Igual — emparejado con #1.
3H3440014942node + ter15Zone 2 (77817)2100100%Watch — RSSI marginal but link quality clean. No action required.Monitorear — RSSI marginal pero link limpio. Sin acción.
All other devices (gateway H2110001289, H3440014941/Z4, H4210005203/climate) report RSSI 6 and linkQuality 100 — healthy.Todos los demás (gateway H2110001289, H3440014941/Z4, H4210005203/clima) reportan RSSI 6 y linkQuality 100 — saludables.

Full device inventory · R&D 6AInventario completo · R&D 6A

SerialSerieModelZoneSensorRSSILink QBatteryOnlineEn líneaLast packetÚltimo paquete
H2110001289gatewaylinelíneaon20:29 UTC
H4210005203h421 + ee894room climateair_temp / RH / VPD / CO₂ / abs_hum6100linelíneaon20:29 UTC
H3440014940 / -2node + ter15Zone 6 (77821)VWC / soil_temp / pore_EC ×2162100%on20:28 UTC
H3440014941 / -2node + ter15Zone 4 (77819)VWC / soil_temp / pore_EC ×26100100%on20:27 UTC
H3440014942 / -2node + ter15Zone 2 (77817)VWC / soil_temp / pore_EC ×22100100%on20:27 UTC

Config & Guardrail AuditAuditoría de Config y Guardarrieles

Active guardrail breaches (computed-alerts)Brechas activas (alertas computadas)

MetricMétricaPeakPicoTargetDurationDuraciónPhase under which alert firedFase de la alerta
pore_EC mS/cm3.954–1217,477 min (≈12 d)Early Flower (target_min breach from 5/8)Flor Temprana (brecha target_min desde 5/8)
air_temp °F82.180–8221,490 min (≈15 d)Early FlowerFlor Temprana
VPD kPa1.201.0–1.221,499 min (≈15 d)Early FlowerFlor Temprana
VWC %59.231–5221,409 min (≈15 d)Early FlowerFlor Temprana
All 4 alerts fire against Early Flower (phase 1030278) bounds, even though the room flipped to Bulking (1030279) on 2026-05-08. The Bulking guardrail band is wider on every one of these metrics, and current values fit Bulking comfortably. This is a config nuance, not a real operational breach — the alert engine appears to be evaluating against the prior phase's targets. Flag for AROYA engineering or for Nelson to set Bulking-active phase explicitly.Las 4 alertas se disparan contra límites de Flor Temprana (fase 1030278), aunque la sala cambió a Engorde (1030279) el 2026-05-08. La banda Engorde es más amplia en cada métrica y los valores actuales encajan cómodamente. Esto es matiz de configuración, no brecha operativa real — el motor de alertas parece evaluar contra objetivos de la fase previa. Marcar a ingeniería AROYA o para que Nelson active explícitamente la fase Engorde.

Phase target ladder (HG 152690)Escalera de objetivos por fase (HG 152690)

PhaseDatesVPDAir temp °FVWC %pore_EC mS/cm
Transition/Veg 14/17–4/241.0–1.280–8245–653–6
Early Flower/Gen4/24–5/081.0–1.280–8231–524–12
Bulking/Veg 2 (current)5/08–5/291.2–1.475–8030–653–7
Ripening/Gen 25/29–6/121.2–1.470–7725–553–6
Harvest6/12–6/131.2–1.470–7525–501.5–3

Recommendations — Owner-TaggedRecomendaciones — Por Responsable

Owner Nelson · infrastructureNelson · infraestructura
1. Add substrate sensors to Zones 1, 3, 5 — the un-instrumented half of the canopy.1. Añadir sensores de sustrato a Zonas 1, 3, 5 — la mitad sin instrumentar del dosel.
50% of the plant zones have no VWC, soil_temp, or pore_EC data. Every irrigation decision is being made on telemetry from the even-numbered half. For an R&D room this defeats the purpose of substrate-driven crop steering.50% de las zonas no tienen datos VWC, soil_temp ni pore_EC. Cada decisión de riego se toma sobre telemetría de la mitad par. Para una sala R&D esto anula el propósito del control de cultivo basado en sustrato.
Owner Nelson · meshNelson · malla
2. Investigate Zone 6 (77821) ter15 pair signal — RSSI 1, link quality 62. Likely fix: re-seat node, clear antenna obstruction, or add a repeater in the Z6 row.2. Investigar señal del par ter15 Zona 6 (77821) — RSSI 1, link 62. Probable arreglo: reasentar nodo, despejar obstrucción de antena, o añadir repetidor en fila Z6.
Devices H3440014940 and H3440014940-2 are still reporting but they're the weakest two radios in the room and the most likely first failure point. Pre-emptive, not urgent.H3440014940 y -2 aún reportan pero son las dos radios más débiles y el primer punto de fallo probable. Preventivo, no urgente.
Grower Bulking · this weekEngorde · esta semana
3. Address rising pore_EC in Zone 4 (+18.7%, now 8.74). Either: cut feed EC for the next 2–3 irrigation cycles, OR run a clear-water flush shot, OR confirm runoff EC vs feed EC to see whether the substrate is stacking or whether feed itself is climbing.3. Atender pore_EC en aumento en Zona 4 (+18.7%, ahora 8.74). O: reducir EC de alimentación los próximos 2–3 ciclos, O: correr shot de agua clara, O: confirmar EC de drenaje vs EC de alimentación para ver si el sustrato acumula o si la alimentación misma sube.
Above the Bulking pore_EC ceiling (7.0) and still trending up. This is the salt-stacking signature that erodes nutrient uptake and reduces flower bulking efficiency.Sobre el techo Engorde (7.0) y aún subiendo. Esta es la firma de apilamiento de sal que erosiona absorción nutricional y reduce eficiencia de engorde.
Grower Bulking · setpointsEngorde · setpoints
4. Tighten the daytime air-temp ceiling. Mean 79.9 °F is fine; daily peaks at 82.6 °F are over the 80 °F Bulking ceiling. Either lower lights-on setpoint by 1.5 °F or increase HVAC capacity at the day-stage peak.4. Apretar el techo de temperatura diurna. Media 79.9 °F está bien; picos 82.6 °F sobre el techo Engorde de 80 °F. Bajar setpoint de luces-on 1.5 °F o aumentar HVAC en pico diurno.
Bulking is generative — overshoot on temp shifts the room toward stretch/vegetative behavior on the warm hours and reduces the day/night differential that the Bulking strategy depends on.Engorde es generativo — sobrepasar temp empuja la sala hacia comportamiento estiramiento/vegetativo en horas cálidas y reduce el diferencial día/noche que la estrategia depende.
Grower Bulking · drybackEngorde · dryback
5. Lengthen P3 dry-down on Zone 4 specifically. Z4 absolute dryback is 14.2% (pp) — below the 15–25% (pp) Bulking band. Add ~20 min to its P3 to bring it to 17–20% (pp). Z2 (22.5% (pp), top edge) and Z6 (18.0% (pp), mid-band) are fine — do not touch their P3.5. Alargar el secado P3 en Zona 4 específicamente. Dryback absoluto de Z4 es 14.2% (pp) — bajo la banda Engorde 15–25% (pp). Añadir ~20 min a su P3 para llevarlo a 17–20% (pp). Z2 (22.5% (pp), tope) y Z6 (18.0% (pp), banda media) están bien — no tocar sus P3.
Z4's shallow dryback is consistent with its EC drift (+18.7%): less of the substrate water column gets refreshed each cycle, so salts accumulate. Deepening Z4's overnight dryback toward 18% (pp) gives the next ramp a cleaner reset and slows the salt stack.El dryback bajo de Z4 es consistente con su deriva CE (+18.7%): menos de la columna de agua del sustrato se refresca por ciclo, así que las sales se acumulan. Profundizar el dryback nocturno de Z4 hacia 18% (pp) da al próximo ciclo de rampa un reset más limpio y frena el apilamiento de sal.
Process AROYA-side · todayLado AROYA · hoy
6. Fix the phase-bounds drift in the alert engine — all 4 active alerts are still evaluating against Early Flower (phase 1030278) bounds 12 days after the room flipped to Bulking (1030279).6. Arreglar la deriva de límites en el motor de alertas — las 4 alertas activas aún evalúan contra límites Flor Temprana (1030278) 12 días después de que la sala cambió a Engorde (1030279).
Either the phase transition is not being persisted into the alert engine, or live target ranges are pinned to the original phase. Real values fit Bulking band today, so the noise is cosmetic — but every minute we leave it is a minute Nelson's dashboard says "warn" without reason.O la transición de fase no se persiste en el motor, o los rangos están fijados a la fase original. Los valores reales encajan banda Engorde hoy, así que el ruido es cosmético — pero cada minuto sin arreglarlo el panel de Nelson dice "warn" sin razón.
Process Cross-system · this weekMulti-sistema · esta semana
7. Close the OpenSprinkler ↔ AROYA loop — the diagnostic doc from 2026-04-17 has been drafted but not delivered. Bring it to the Thu 11 AM Calendly with Nelson and decide: bridge, point at existing integration, or park.7. Cerrar el loop OpenSprinkler ↔ AROYA — el diagnóstico del 2026-04-17 está redactado pero no entregado. Llevarlo a la cita Calendly jue 11 AM con Nelson y decidir: puente, apuntar a integración existente, o pausar.
OpenSprinkler is currently driving irrigation but AROYA does not see the feedback loop — which means every Bulking-phase shot adjustment we suggest above is being made downstream of an integration AROYA can't observe.OpenSprinkler maneja riego pero AROYA no ve el loop — significa que cada ajuste de shot Engorde que sugerimos arriba se hace aguas abajo de una integración que AROYA no observa.

Open Questions for Thursday's MeetingPreguntas Abiertas para la Reunión del Jueves

  1. Which zone(s) hold LA Kush Cake vs Papaya Trop Cherries?¿Qué zona(s) tienen LA Kush Cake vs Papaya Trop Cherries? The strain-zone map turns the Loose-Bud Issue Report from a directional hypothesis into a hard finding — if LA Kush Cake sits in Z4 (pore_EC 8.74, +18.7%), the EC stack story is the smoking gun.El mapa zona-cepa convierte el Reporte de Brote Suelto de hipótesis direccional en hallazgo duro — si LA Kush Cake está en Z4 (pore_EC 8.74, +18.7%), la pila CE es el arma humeante.
  2. Plan for sensoring Zones 1, 3, 5 — budget, install timeline, who?Plan para sensorizar Zonas 1, 3, 5 — presupuesto, plazo de instalación, ¿quién?
  3. Is the Z6 mesh weakness physical (antenna obstruction) or topological (too far from gateway)? Walk-through with the AROYA mobile app while we're talking.¿La debilidad de malla Z6 es física (obstrucción de antena) o topológica (lejos del gateway)? Recorrido con la app móvil AROYA durante la llamada.
  4. Does Nelson want us to build the OpenSprinkler ↔ AROYA bridge in-house, point at an existing third-party integration, or park the project?¿Nelson quiere que construyamos el puente OpenSprinkler ↔ AROYA internamente, apuntar a una integración existente, o pausar el proyecto?
  5. Should the room be moved into Bulking target ranges explicitly inside AROYA, or is this an alert-engine config bug we should file?¿La sala debe moverse a rangos Engorde explícitamente en AROYA, o es un bug de configuración del motor de alertas para reportar?

Data Quality & CoverageCalidad y Cobertura de Datos

SourceFuenteCoverageCoberturaCadenceCadenciaStatusEstado
Room-level climate (VPD/temp/RH/CO₂/abs_hum)Clima nivel sala14 d · 480 samples/series~42 min binned, 3 min rawcompletecompleto
Substrate (Z2, Z4, Z6)Sustrato (Z2, Z4, Z6)14 d · 480 samples/zone3 min rawcompletecompleto
Substrate (Z1, Z3, Z5)Sustrato (Z1, Z3, Z5)no sensors installedsin sensores
Drip volume / drain volumeVolumen drip / drenajeno sensors installedsin sensores
Drip EC / drain ECCE drip / CE drenajeno sensors installedsin sensores
DLI / PAR / solar_quantumDLI / PAR / quántum solarno sensors installedsin sensores
Harvest events (manual + auto irrigation)Eventos cosecha (riego)0 events in windowno events logged via AROYAsin eventos registrados
Journal entriesEntradas diario0 in windownoneninguno
Device telemetry (battery/RSSI/link)Telemetría dispositivosAll 8 reporting3 mincompletecompleto