GTI Danville PA — Device Fleet Health GTI Danville PA — Salud de la Flota

Facility 3003 · GTI - PA · Org 331 · Audit window 2026-05-06 → 2026-05-20 · Snapshot as of 2026-06-01 Instalación 3003 · GTI - PA · Org 331 · Ventana 2026-05-06 → 2026-05-20 · Captura 2026-06-01

Headline — Read This FirstResumen — Lea Esto Primero

Correction from the prior report.Corrección del informe anterior. The 2026-05-20 "GTI Danville Device Fleet Health" report I sent earlier was pulled against AROYA facility 3684 (GTI - DGF), which is a different site — 13 rooms, ~50 devices. This corrected report covers the actual GTI Danville PA facility (AROYA id 3003, 44 rooms, 1,515 devices). The earlier "Gateway 119178" reference is also from DGF (3684), not PA — 119178 does not exist at PA. Your PA fleet runs on the 8 gateways listed below. El informe del 2026-05-20 se extrajo de la instalación AROYA 3684 (GTI - DGF), que es un sitio distinto. Este informe corregido cubre la instalación real GTI Danville PA (AROYA 3003, 44 salas, 1.515 dispositivos). La pasarela 119178 también era de DGF, no de PA.

Devices
1,515
1,515 across 44 rooms1.515 en 44 salas
Active roomsSalas activas
38/44
Reporting env dataReportan datos
Critical flagsCríticas
2
VWC anomaliesAnomalías VWC
Gateways
8
+ 8 sinks, 76 repeaters

Fleet CompositionComposición de la Flota

By modelPor modelo

node
712
ter12
645
ter15
27
repeater
76
atm14
39
gateway
8
sink
8

node = AROYA mesh sensor base; ter12 / ter15 = substrate probes; atm14 = climate sensor; repeater = mesh repeater (H340-series run on battery; legacy H11x are PoE); gateway + sink = Wirepas backbone (paired). node = base de sensor de malla; ter12 / ter15 = sondas de sustrato; atm14 = sensor climático; repeater = repetidor (serie H340 a batería; H11x antiguos PoE); gateway + sink = columna Wirepas.

Critical Flags & AnomaliesAlertas Críticas y Anomalías

SeveritySeveridadRoomSalaObservationObservación
CRITICALFlower 23Room-avg VWC 8.0% — likely no crop / sensors dry / uncalibrated
CRITICALFlower 32Room-avg VWC 7.2% — likely no crop / sensors dry / uncalibrated

Partial dropouts (stale zones)Caídas parciales

  • Zone 60702 in Flower 25 — last reading 2026-06-01T02:27Z; ~18h stale vs room median 20:06Z

Per-Room Health Summary (Active Rooms)Resumen de Salud por Sala (Activas)

RoomSala Devices Substrate probesSondas atm14 Nodes VWC % Temp °F VPD StatusEstado
Flower 1 14 1 1 11 72.6 1.17 ReportingReportando
Flower 5 30 14 1 14 39.5 80.4 1.10 ReportingReportando
Flower 6 30 14 1 14 70.2 1.32 ReportingReportando
Flower 7 30 14 1 14 63.3 80.9 1.76 ReportingReportando
Flower 8 43 27 1 14 59.1 77.5 1.39 ReportingReportando
Flower 9 30 14 1 14 55.6 74.9 1.03 ReportingReportando
Flower 10 30 15 1 13 62.4 78.2 1.26 ReportingReportando
Flower 11 30 14 1 14 44.5 75.6 1.28 ReportingReportando
Flower 12 30 14 1 14 39.0 79.0 1.29 ReportingReportando
Flower 13 30 14 1 14 46.7 76.7 1.16 ReportingReportando
Flower 14 30 14 1 14 83.2 70.7 1.50 ReportingReportando
Flower 15 30 14 1 14 33.4 71.1 1.47 ReportingReportando
Flower 16 30 14 1 14 41.5 71.4 1.39 ReportingReportando
Flower 17 30 13 1 15 53.3 72.0 1.40 ReportingReportando
Flower 18 30 14 1 14 57.8 71.9 1.40 ReportingReportando
Flower 19 31 14 1 14 57.0 72.3 1.45 ReportingReportando
Flower 20 30 14 1 14 57.3 72.8 1.36 ReportingReportando
Flower 21 30 14 1 14 44.2 73.4 1.44 ReportingReportando
Flower 22 30 14 1 14 53.0 74.6 1.42 ReportingReportando
Flower 23 43 21 1 20 8.0 72.0 1.46 Anomaly: VWC <10%Anomalía: VWC <10%
Flower 24 42 20 1 20 31.9 68.9 1.18 ReportingReportando
Flower 25 42 20 1 20 37.3 72.0 1.22 ReportingReportando
Flower 26 42 20 1 20 45.7 71.4 0.89 ReportingReportando
Flower 27 43 21 1 20 43.3 73.3 1.06 ReportingReportando
Flower 28 42 20 1 20 44.0 78.3 0.76 ReportingReportando
Flower 29 42 20 1 20 40.2 76.6 1.04 ReportingReportando
Flower 30 42 20 1 20 40.6 ReportingReportando
Flower 31 42 20 1 20 44.7 79.1 0.97 ReportingReportando
Flower 32 42 20 1 20 7.2 Anomaly: VWC <10%Anomalía: VWC <10%
Flower 33 42 20 1 20 26.6 79.1 1.23 ReportingReportando
Flower 34 42 20 1 20 44.2 72.4 1.24 ReportingReportando
Flower 35 42 20 1 20 47.4 73.7 1.27 ReportingReportando
Flower 36 42 20 1 20 51.2 71.9 1.17 ReportingReportando
Flower 37 42 20 1 20 52.2 72.0 0.96 ReportingReportando
Flower 38 42 20 1 20 46.1 74.3 1.15 ReportingReportando
Flower 39 42 20 1 20 49.8 76.3 1.13 ReportingReportando
Flower 40 42 20 1 20 53.6 77.7 0.76 ReportingReportando
Clone 1 2 0 1 0 78.3 0.84 ReportingReportando
ReportingReportando WarningAdvertencia Critical anomalyAnomalía crítica Non-cultivation / no signalSin cultivo = per-zone readings sampled in this audit= zonas muestreadas

Inactive Rooms (No Environmental Signal)Salas Inactivas

RoomSalaDevicesSubstrate probesSondasatm14NodesVWCTempVPDStatus
Flower 2 0 0 0 0 No signalSin señal
Flower 3 0 0 0 0 No signalSin señal
Flower 4 0 0 0 0 No signalSin señal
Hallways 36 0 0 0 Non-cultivationNo cultivo
Very Dead Storage 90 20 1 64 Non-cultivationNo cultivo
Storage 0 0 0 0 Non-cultivationNo cultivo

Hallways / Storage / Very Dead Storage are non-cultivation areas — no signal expected. Flower 2/3/4 and Flower 30 show device inventory but null environmental averages — likely between runs, controllers offline, or zone-mapping needs to be re-verified. Pasillos / Almacén son áreas sin cultivo. Flower 2/3/4 y Flower 30 tienen inventario pero sin promedios climáticos — probablemente entre cosechas.

Mesh Backbone — Gateways at PAColumna de Malla — Pasarelas en PA

8 gateways serve the PA mesh — 4 paired in Hallways (room 9125) and 4 paired in Very Dead Storage (room 11368). Each gateway has a matching SINK device — that's the Wirepas pattern, not double-counting. 8 pasarelas sirven la malla de PA — 4 en Pasillos (9125) y 4 en Very Dead Storage (11368). Cada una tiene un SINK pareado.

IDSerialMounted inUbicación
119920H2100004550Hallways
88433H2100004119Hallways
134282H2100004715Hallways
125443H2100004738Hallways
68548H2100002562Very Dead Storage
56685H2100002497Very Dead Storage
80235H2100004006Very Dead Storage
80236H2100004008Very Dead Storage

76 PoE mesh repeaters distributed across the cultivation rooms carry the node traffic to the gateway cluster. nextHop diversity confirmation requires a per-device topology pull (deferred — see Data Quality below). 76 repetidores distribuyen el tráfico hacia las pasarelas (los de la serie H340 funcionan a batería).

Recommended ActionsAcciones Recomendadas

  1. Walk Flower 23 and Flower 32 today.Inspeccionar F23 y F32 hoy. Room-avg VWC of 8.0% (F23) and 7.2% (F32) is either: (a) the room is between cycles and substrate is bone-dry, (b) drip lines aren't running, or (c) probes are out-of-substrate / uncalibrated. Quickest triage: confirm by eye whether plants are in the room. VWC promedio 8% (F23) y 7.2% (F32) — probablemente entre cosechas o sondas fuera de sustrato.
  2. Check zone 60702 in Flower 25.Revisar zona 60702 en F25. Its last reading is ~18 hours stale vs the rest of the room. Probably a single device dropout — sensor swap or zone-power check. Lectura ~18h obsoleta vs el resto de la sala.
  3. Flower 2, 3, 4, 30 — confirm intent.Confirmar intención de F2/3/4/30. Devices are inventoried but no environmental signal. If these rooms should be active, the gateway-side mapping or controllers need a look. If they're correctly idle, no action. Tienen dispositivos pero sin señal climática.
  4. High EC stack in mid-flower rooms.EC alta en mid-flower. Flower 11 / 13 / 17 are running room-avg pore-EC 6.1–6.3 mS. That's stacked for finishing weeks — if these rooms aren't in ripening, runoff EC needs a check before salt damage. F11/13/17 con EC 6.1–6.3 mS — verificar fase y runoff.
  5. Mesh-level radio audit deferred.Auditoría de radio diferida. Per-device RSSI / battery / travel-time / nextHop parent diversity needs a 14-day per-device chart pull (10,605 API calls at PA's scale). That's queued for a follow-up run with proper throttling. This snapshot tells you which zones are reporting now, not the full radio-link audit. El audit de radio por dispositivo está pendiente — 14d × 1.515 dispositivos requiere un pull dedicado.

Data Quality & ScopeCalidad de Datos y Alcance

What this report coversQué cubre

  • Full device inventory for facility 3003 (1,515 devices) — model, room, zone, serial.Inventario completo (1.515 dispositivos).
  • Per-room environmental averages over the most recent 14-day window (room-overview endpoint).Promedios por sala (14d).
  • Per-zone current-reading sampling for 24 of the 38 active rooms (●) — confirms zones are reporting at 2026-06-01 cadence.Lecturas por zona en 24 de 38 salas activas.

What this report does NOT cover (deferred)No cubierto (pendiente)

  • Per-device RSSI / battery / travel-time / data-gap histograms over the 14d window — the proper "mesh health" audit. Skipped because 1,515 devices × 7 two-day chunks = 10,605 API calls, throttled at ~50 req/min = ~3.5 hours of pulls. To be run on a longer-lived process.RSSI / batería / viaje por dispositivo — diferido por escala.
  • AROYA-native alerts (/alerts endpoint returns HTTP 404 for facility 3003 — either the endpoint is not enabled on this tenant or no alert rules configured. Falling back on chart-based anomaly detection above).Alertas nativas AROYA no disponibles (HTTP 404).
  • nextHop diversity confirmation across the 76 repeaters — requires the per-device pull above.Diversidad de nextHop — requiere pull por dispositivo.