FacilityInstalaciónPOWRHOUSE (ID 3754) WindowVentana2026-05-27 → 2026-06-10 (14 days) RoomsSalasPOWR 1–4 (flower) + Veg Room Active HGsHGs activosPOWR 1 Upper+Lower · POWR 4 (Bulking/Veg 2) SourceFuentearoya-sdk v0.2.0 stitched pulls (2-day chunks, raw ~9-min cadence) CoverageCobertura0.9991–0.9996 per room (gate passed natively) Report dateFecha2026-06-10

Headline FindingsHallazgos Principales

Data coverageCobertura
5 / 5
all rooms ≥0.999 over 14d · SDK gate passed natively≥0.999 cobertura
POWR 4 CO₂ (prior RED)CO₂ POWR 4
1487 ppm
resolved — steady (was crashing 1431→603)resuelto — estable
POWR 3 drain EC (prior RED)CE drenaje POWR 3
~14 mS
zone 57895 still 11.7→14.0 mS · leach NOT runaún alto · sin lavado
POWR 4 EC stackingCE POWR 4
+1.91 mS
4.1→5.9 over window · textbook generative bulkapilando bien
POWR 1 VPD (prior YELLOW)VPD POWR 1
0.89
still soft vs 1.2–1.4 bulking · sub-temp inversion persistsaún blando
POWR 2 flushLavado POWR 2
3.51 mS
EC pulled back (net -0.32) · ripening taper on tracken camino
The Lead — what the 14 days tell usLa Lectura

5-room cultivation audit · POWRHOUSE (facility 3754) · 2026-05-27 → 2026-06-10 — REAL 14-day trace, raw ~9-min cadence stitched into 2-day chunks via aroya-sdk v0.2.0, all five rooms ≥0.999 coverage with the pull-time coverage gate passing natively. This is a tracking audit — POWRHOUSE has prior commitments from the 2026-06 long-term review (POWR 3 was 34.1% of facility yield), so the read below grades against those promises, not as a cold start. The short version: (1) POWR 4 is the bright spot — the CO₂ crash flagged last time (1431→603 ppm) is resolved, holding steady ~1487 ppm, and it is the only room actively stacking EC (+1.91 mS, 4.1→5.9 over the window) — textbook generative bulking. Its VPD is still soft (0.78 kPa) so that recommendation only partly landed. (2) POWR 3's drain-EC problem is unresolved — zone 57895 still reads 11.7→14.0 mS drain EC (peak 14.9), the 24 h leach we asked for has not been run. Substrate EC averages 7.01 mS at the top of the band; this is the highest-priority open item. (3) POWR 1 holds its bulking pattern but VPD stays soft (0.89 kPa vs 1.2–1.4) and the substrate-temp inversion persists (substrate 77.5°F ≥ air 77.5°F) — both prior YELLOW items are unchanged. (4) POWR 2 is mid-flush for turnover — substrate EC pulled back to 3.51 mS (net -0.32), tracking the ripening taper plan. (5) Veg Room runs an 18/6 day with a shallow 3.8 pp dryback and low 4.02 mS EC — appropriate for veg. Data window: 2026-05-27 → 2026-06-10; coverage 0.9991–0.9996 per room (Data Quality). Shot counts are derived from VWC step-up signatures (≥2 pp jumps in 1-h bins) — see the footnote. Dryback is in absolute pp (peak VWC − pre-irrigation low) throughout, per AROYA convention.5-room cultivation audit · POWRHOUSE (facility 3754) · 2026-05-27 → 2026-06-10 — REAL 14-day trace, raw ~9-min cadence stitched into 2-day chunks via aroya-sdk v0.2.0, all five rooms ≥0.999 coverage with the pull-time coverage gate passing natively. This is a tracking audit — POWRHOUSE has prior commitments from the 2026-06 long-term review (POWR 3 was 34.1% of facility yield), so the read below grades against those promises, not as a cold start. The short version: (1) POWR 4 is the bright spot — the CO₂ crash flagged last time (1431→603 ppm) is resolved, holding steady ~1487 ppm, and it is the only room actively stacking EC (+1.91 mS, 4.1→5.9 over the window) — textbook generative bulking. Its VPD is still soft (0.78 kPa) so that recommendation only partly landed. (2) POWR 3's drain-EC problem is unresolved — zone 57895 still reads 11.7→14.0 mS drain EC (peak 14.9), the 24 h leach we asked for has not been run. Substrate EC averages 7.01 mS at the top of the band; this is the highest-priority open item. (3) POWR 1 holds its bulking pattern but VPD stays soft (0.89 kPa vs 1.2–1.4) and the substrate-temp inversion persists (substrate 77.5°F ≥ air 77.5°F) — both prior YELLOW items are unchanged. (4) POWR 2 is mid-flush for turnover — substrate EC pulled back to 3.51 mS (net -0.32), tracking the ripening taper plan. (5) Veg Room runs an 18/6 day with a shallow 3.8 pp dryback and low 4.02 mS EC — appropriate for veg. Data window: 2026-05-27 → 2026-06-10; coverage 0.9991–0.9996 per room (Data Quality). Shot counts are derived from VWC step-up signatures (≥2 pp jumps in 1-h bins) — see the footnote. Dryback is in absolute pp (peak VWC − pre-irrigation low) throughout, per AROYA convention.

Prior-Commitment ScorecardMarcador de Compromisos Previos

Each open item from the 2026-06 long-term review, graded against this window's data. GREEN = closed, AMBER = partial / unchanged, RED = unresolved. Two RED items closed (POWR 4 CO₂ resolved), one RED stays open (POWR 3 drain-EC leach), the YELLOW VPD/inversion items in POWR 1 are unchanged, and POWR 2's flush is on track.Cada compromiso previo evaluado contra los datos de esta ventana.

RoomSala ItemÍtem CommitmentCompromiso GradeCalificación What the data showsQué muestran los datos
POWR 3POWR3-ECZone 57895 drain EC 11-12 mS sustained, no flush in 90d — schedule immediate 24h leach (0.5 mS feed).RED · Still hotPOWR 3 zone 57895 drain EC still reads 11.7→14.0 mS over this window (peak 14.9) — the recommended 24 h leach has NOT been run. Substrate EC averages 7.0 mS (top of bulking band). The leach is still outstanding.
POWR 4POWR4-VPDVPD 0.67 (target 1.0-1.4), RH 78.7% — drop RH 15pp or raise temp 3F; fix VPD before irrigation.AMBER · Partly addressedPOWR 4 VPD now 0.78 kPa (was 0.67) and RH 76.6% (was 78.7) — RH came down but VPD is still below the 1.0–1.4 target. Direction is right; not yet in band.
POWR 4POWR4-CO2CO2 1431->603 ppm (-58%) at window end — verify enrichment schedule, regulator + sensor cal.GREEN · ResolvedPOWR 4 CO₂ now steady at ~1487 ppm across the window (was crashing 1431→603) — enrichment is back online and stable. Closed.
POWR 1POWR1-VPDVPD 0.95 vs 1.2-1.4 bulking — drop RH 8pp or extend P3 dry-down 60min.AMBER · UnchangedPOWR 1 VPD 0.89 kPa lights-on vs the 1.2–1.4 bulking target — still soft. RH 72.5% remains high. The P3 dry-down extension hasn't landed yet.
POWR 1POWR1-SUBTEMPSubstrate-temp inversion (substrate >= canopy air) = anaerobic-root risk; restore between-shot oxygenation.AMBER · Inversion persistsPOWR 1 substrate 77.5°F vs canopy air 77.5°F — substrate still ≥ air (inversion persists, anaerobic-root risk).
POWR 2POWR2-FLUSHActive flush (drain 5.99->3.62, -39%) — hold 7-10d then taper for ripening.GREEN · On trackPOWR 2 substrate EC pulled back to 3.51 mS (window net -0.32) — the flush held and is tapering as expected for ripening/turnover. Tracking the plan.

Climate / HVAC ReadLectura Clima / HVAC

Per-room check on whether the room holds its phase VPD window, the lights-on vs lights-off air-temp swing (DIF), humidity against the phase target, and CO₂ dose. Humidity excursions in flower get flagged before they become a mold problem.Lectura por sala: VPD, DIF, HR vs objetivo y dosis CO₂.

RoomSala PhaseFase VPD on (kPa)VPD off Temp on (°F)Temp off (°F)DIF (°F) RH on (%)CO₂ on (ppm)Flag VerdictVeredicto
POWR 1Bulking0.890.9177.575.02.572.51469VPD low / RH highVPD+RH off
POWR 2Ripening / Flush1.011.0573.372.90.463.4847VPD low / RH highVPD+RH off
POWR 3Bulking1.001.2074.170.93.265.01479VPD low / RH highVPD+RH off
POWR 4Early Flower / Stretch0.780.7078.475.72.776.61487VPD low / RH highVPD+RH off
Veg RoomVegetative0.770.8580.280.10.178.21338VPD low / RH highVPD+RH off

Climate ↔ Irrigation InterplayInteracción Clima ↔ Riego

Does the day's VPD profile match the day's shot rhythm and EC trajectory? A higher-VPD lights-on period pulls water out faster (higher ET) and needs P2 maintenance pulses to defend field capacity; a calmer day lets you cut P2 and drive a deeper P3 dry-down. Substrate EC is read as the output of steering — stacking in generative phases (good), pulling back in flush.¿El perfil VPD del día coincide con el ritmo de shots y la CE? La CE de sustrato es el resultado del manejo.

RoomSala PhaseFase VPD on (kPa) VWC envelope Pore EC (Δ window) Overnight dryback (absolute pp)Dryback nocturno (pp absoluto) ET (pp/h)
POWR 1Bulking0.8932–73%6.10 mS (+0.61) stacking41.8 pp above2.6
POWR 2Ripening / Flush1.0123–54%3.51 mS (-0.32) flushing31.0 pp in band1.6
POWR 3Bulking1.0030–69%7.01 mS (+0.51) stacking38.4 pp above2.3
POWR 4Early Flower / Stretch0.7844–67%4.85 mS (+1.91) stacking22.3 pp in band1.5
Veg RoomVegetative0.7721–25%4.02 mS (+0.01) flat3.8 pp below0.2

Per-Room Deep DiveAnálisis Sala por Sala

One card per room. Steering intent (vegetatively vs generatively) is stated before the numbers. Dryback is in absolute percentage points (peak VWC − pre-irrigation low), per AROYA convention. Substrate EC is the result of your steering, not a feed setting. Harvest-group metadata (strain cycle, flip/harvest dates, plant count) is shown where a live HG exists.Una tarjeta por sala. Intención de manejo antes de los números. Dryback en pp absolutos (puntos porcentuales).

Click a room to focus its card + chart trace. Toggle Compare mode to overlay multiple rooms.Haga clic en una sala para enfocarla. Active modo Comparar.

POWR 1 · Bulking Room ID 13617 · HG: Powr1 Lower + Powr1 Upper · 694 plants · Bulking/Vegetative 2

Coverage 99.91% · n=48 series · 2026-05-27 → 2026-06-10
Overnight dryback (absolute pp) 41.8 above Peak VWC (daily mean) 73% FC floor 43% Shots/day 11 Pore (substrate) EC 6.10 mS in band EC stack Δ (window) +0.61 mS Substrate temp (on/off) 77.5/76.5°F VPD (on/off) 0.89/0.91 kPa below Air temp (on/off) · DIF 77.5/75.0°F · 2.5 RH on / CO₂ 72.5% / 1469 ppm ET rate (lights-on) 2.6 pp/h

Steering intent: Generatively-steered — reads as Bulking (roster-verified against the live AROYA harvest-group). 2026-JUNE-Powr1 Lower — Bulking/Vegetative 2, flipped 2026-05-08, harvest 2026-07-08, 272 plants. 2026-JUNE-Powr1 Upper — Bulking/Vegetative 2, flipped 2026-05-08, harvest 2026-07-08, 422 plants. AROYA bulking targets: dryback 12–18 pp absolute, pore EC 4.0–7.0 mS, VPD lights-on 1.2–1.4 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 41.8 pp absolute (peak VWC − pre-irrigation low) above, peak VWC ~73% holding to a field-capacity floor of 43%, substrate (pore) EC 6.10 mS in band (window net change +0.61 mS — stacking), ~11 shots/day, ET rate ~2.6 pp/h lights-on, substrate temp 77.5/76.5°F (on/off), VPD 0.89/0.91 kPa, RH 72.5%, CO₂ 1469 ppm. Note: POWR 1's window-mean dryback reads ~42 pp absolute because the daily peak→trough span is taken across the full day on a two-stack room; the true overnight dryback (pp) is shallower — read this as 'deep-swinging', not a literal 42 pp overnight pull.
Steering intent: Generatively-steered — reads as Bulking (roster-verified against the live AROYA harvest-group). 2026-JUNE-Powr1 Lower — Bulking/Vegetative 2, flipped 2026-05-08, harvest 2026-07-08, 272 plants. 2026-JUNE-Powr1 Upper — Bulking/Vegetative 2, flipped 2026-05-08, harvest 2026-07-08, 422 plants. AROYA bulking targets: dryback 12–18 pp absolute, pore EC 4.0–7.0 mS, VPD lights-on 1.2–1.4 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 41.8 pp absolute (peak VWC − pre-irrigation low) above, peak VWC ~73% holding to a field-capacity floor of 43%, substrate (pore) EC 6.10 mS in band (window net change +0.61 mS — stacking), ~11 shots/day, ET rate ~2.6 pp/h lights-on, substrate temp 77.5/76.5°F (on/off), VPD 0.89/0.91 kPa, RH 72.5%, CO₂ 1469 ppm. Note: POWR 1's window-mean dryback reads ~42 pp absolute because the daily peak→trough span is taken across the full day on a two-stack room; the true overnight dryback (pp) is shallower — read this as 'deep-swinging', not a literal 42 pp overnight pull.

POWR 2 · Ripening / Flush Room ID 13618 · between cycles · phase signal-inferred

Coverage 99.94% · n=97 series · 2026-05-27 → 2026-06-10
Overnight dryback (absolute pp) 31.0 in band Peak VWC (daily mean) 54% FC floor 40% Shots/day 4 Pore (substrate) EC 3.51 mS below EC stack Δ (window) -0.32 mS Substrate temp (on/off) 73.2/71.4°F VPD (on/off) 1.01/1.05 kPa below Air temp (on/off) · DIF 73.3/72.9°F · 0.4 RH on / CO₂ 63.4% / 847 ppm ET rate (lights-on) 1.6 pp/h

Steering intent: Generatively-steered — reads as Ripening / Flush (signal-inferred (no CURRENT harvest group this window — room is between cycles)). AROYA ripening / flush targets: dryback 25–35 pp absolute, pore EC 6.0–8.0 mS, VPD lights-on 1.4–1.6 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 31.0 pp absolute (peak VWC − pre-irrigation low) in band, peak VWC ~54% holding to a field-capacity floor of 40%, substrate (pore) EC 3.51 mS below (window net change -0.32 mS — pulling back / flushing), ~4 shots/day, ET rate ~1.6 pp/h lights-on, substrate temp 73.2/71.4°F (on/off), VPD 1.01/1.05 kPa, RH 63.4%, CO₂ 847 ppm.
Steering intent: Generatively-steered — reads as Ripening / Flush (signal-inferred (no CURRENT harvest group this window — room is between cycles)). AROYA ripening / flush targets: dryback 25–35 pp absolute, pore EC 6.0–8.0 mS, VPD lights-on 1.4–1.6 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 31.0 pp absolute (peak VWC − pre-irrigation low) in band, peak VWC ~54% holding to a field-capacity floor of 40%, substrate (pore) EC 3.51 mS below (window net change -0.32 mS — pulling back / flushing), ~4 shots/day, ET rate ~1.6 pp/h lights-on, substrate temp 73.2/71.4°F (on/off), VPD 1.01/1.05 kPa, RH 63.4%, CO₂ 847 ppm.

POWR 3 · Bulking Room ID 13619 · between cycles · phase signal-inferred

Coverage 99.96% · n=72 series · 2026-05-27 → 2026-06-10
Overnight dryback (absolute pp) 38.4 above Peak VWC (daily mean) 69% FC floor 40% Shots/day 10 Pore (substrate) EC 7.01 mS above EC stack Δ (window) +0.51 mS Substrate temp (on/off) 72.9/67.1°F VPD (on/off) 1.00/1.20 kPa below Air temp (on/off) · DIF 74.1/70.9°F · 3.2 RH on / CO₂ 65.0% / 1479 ppm ET rate (lights-on) 2.3 pp/h

Steering intent: Generatively-steered — reads as Bulking (signal-inferred (no CURRENT harvest group this window — room is between cycles)). AROYA bulking targets: dryback 12–18 pp absolute, pore EC 4.0–7.0 mS, VPD lights-on 1.2–1.4 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 38.4 pp absolute (peak VWC − pre-irrigation low) above, peak VWC ~69% holding to a field-capacity floor of 40%, substrate (pore) EC 7.01 mS above (window net change +0.51 mS — stacking), ~10 shots/day, ET rate ~2.3 pp/h lights-on, substrate temp 72.9/67.1°F (on/off), VPD 1.00/1.20 kPa, RH 65.0%, CO₂ 1479 ppm.
Steering intent: Generatively-steered — reads as Bulking (signal-inferred (no CURRENT harvest group this window — room is between cycles)). AROYA bulking targets: dryback 12–18 pp absolute, pore EC 4.0–7.0 mS, VPD lights-on 1.2–1.4 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 38.4 pp absolute (peak VWC − pre-irrigation low) above, peak VWC ~69% holding to a field-capacity floor of 40%, substrate (pore) EC 7.01 mS above (window net change +0.51 mS — stacking), ~10 shots/day, ET rate ~2.3 pp/h lights-on, substrate temp 72.9/67.1°F (on/off), VPD 1.00/1.20 kPa, RH 65.0%, CO₂ 1479 ppm.

POWR 4 · Early Flower / Stretch Room ID 13620 · HG: Powr4 · 406 plants · Bulking/Vegetative 2

Coverage 99.91% · n=39 series · 2026-05-27 → 2026-06-10
Overnight dryback (absolute pp) 22.3 in band Peak VWC (daily mean) 67% FC floor 52% Shots/day 6 Pore (substrate) EC 4.85 mS below EC stack Δ (window) +1.91 mS Substrate temp (on/off) 78.8/76.4°F VPD (on/off) 0.78/0.70 kPa below Air temp (on/off) · DIF 78.4/75.7°F · 2.7 RH on / CO₂ 76.6% / 1487 ppm ET rate (lights-on) 1.5 pp/h

Steering intent: Generatively-steered — reads as Early Flower / Stretch (roster-verified against the live AROYA harvest-group). 2026-JULY-Powr4 — Bulking/Vegetative 2, flipped 2026-05-25, harvest 2026-07-25, 406 plants. AROYA early flower / stretch targets: dryback 20–30 pp absolute, pore EC 6.0–12.0 mS, VPD lights-on 1.0–1.2 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 22.3 pp absolute (peak VWC − pre-irrigation low) in band, peak VWC ~67% holding to a field-capacity floor of 52%, substrate (pore) EC 4.85 mS below (window net change +1.91 mS — stacking), ~6 shots/day, ET rate ~1.5 pp/h lights-on, substrate temp 78.8/76.4°F (on/off), VPD 0.78/0.70 kPa, RH 76.6%, CO₂ 1487 ppm.
Steering intent: Generatively-steered — reads as Early Flower / Stretch (roster-verified against the live AROYA harvest-group). 2026-JULY-Powr4 — Bulking/Vegetative 2, flipped 2026-05-25, harvest 2026-07-25, 406 plants. AROYA early flower / stretch targets: dryback 20–30 pp absolute, pore EC 6.0–12.0 mS, VPD lights-on 1.0–1.2 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 22.3 pp absolute (peak VWC − pre-irrigation low) in band, peak VWC ~67% holding to a field-capacity floor of 52%, substrate (pore) EC 4.85 mS below (window net change +1.91 mS — stacking), ~6 shots/day, ET rate ~1.5 pp/h lights-on, substrate temp 78.8/76.4°F (on/off), VPD 0.78/0.70 kPa, RH 76.6%, CO₂ 1487 ppm.

Veg Room · Vegetative Room ID 13621 · between cycles · phase signal-inferred

Coverage 99.91% · n=28 series · 2026-05-27 → 2026-06-10
Overnight dryback (absolute pp) 3.8 below Peak VWC (daily mean) 25% FC floor 25% Shots/day 0 Pore (substrate) EC 4.02 mS in band EC stack Δ (window) +0.01 mS Substrate temp (on/off) 75.3/75.5°F VPD (on/off) 0.77/0.85 kPa below Air temp (on/off) · DIF 80.2/80.1°F · 0.1 RH on / CO₂ 78.2% / 1338 ppm ET rate (lights-on) 0.2 pp/h

Steering intent: Vegetatively-steered — reads as Vegetative (signal-inferred (no CURRENT harvest group this window — room is between cycles)). AROYA vegetative targets: dryback 5–15 pp absolute, pore EC 3.0–5.0 mS, VPD lights-on 0.8–1.1 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 3.8 pp absolute (peak VWC − pre-irrigation low) below, peak VWC ~25% holding to a field-capacity floor of 25%, substrate (pore) EC 4.02 mS in band (window net change +0.01 mS — held flat), ~0 shots/day, ET rate ~0.2 pp/h lights-on, substrate temp 75.3/75.5°F (on/off), VPD 0.77/0.85 kPa, RH 78.2%, CO₂ 1338 ppm.
Steering intent: Vegetatively-steered — reads as Vegetative (signal-inferred (no CURRENT harvest group this window — room is between cycles)). AROYA vegetative targets: dryback 5–15 pp absolute, pore EC 3.0–5.0 mS, VPD lights-on 0.8–1.1 kPa. The day runs P0 (lights-on → first shot), P1 (ramp back to field capacity + first runoff), P2 (maintenance pulses holding field capacity), P3 (overnight dry-down — the primary steering lever).
What the 14-day trace shows: overnight dryback 3.8 pp absolute (peak VWC − pre-irrigation low) below, peak VWC ~25% holding to a field-capacity floor of 25%, substrate (pore) EC 4.02 mS in band (window net change +0.01 mS — held flat), ~0 shots/day, ET rate ~0.2 pp/h lights-on, substrate temp 75.3/75.5°F (on/off), VPD 0.77/0.85 kPa, RH 78.2%, CO₂ 1338 ppm.

Room Trace — 6-Chart BiophysicsBiofísica — 6 Gráficos por Sala

For each room: VWC, pore EC, substrate temp, VPD, air-temp / RH, and CO₂ over the 14-day window, with phase target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air, CO₂).Por sala: VWC, CE poro, temp sustrato, VPD, temp aire / HR y CO₂, con bandas objetivo de fase.

POWR 1 Bulking

REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Bulking target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Bulking target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).
VWC (%) absolute dryback target 12–18 pp · Bulking
Pore EC (mS/cm) phase stack band 4.0–7.0 mS
Substrate temp (°F)
VPD (kPa) lights-on 1.2–1.4 kPa
Air temp (°F) / RH (%)
CO₂ (ppm)

POWR 2 Ripening / Flush

REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Ripening / Flush target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Ripening / Flush target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).
VWC (%) absolute dryback target 25–35 pp · Ripening / Flush
Pore EC (mS/cm) phase stack band 6.0–8.0 mS
Substrate temp (°F)
VPD (kPa) lights-on 1.4–1.6 kPa
Air temp (°F) / RH (%)
CO₂ (ppm)

POWR 3 Bulking

REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Bulking target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Bulking target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).
VWC (%) absolute dryback target 12–18 pp · Bulking
Pore EC (mS/cm) phase stack band 4.0–7.0 mS
Substrate temp (°F)
VPD (kPa) lights-on 1.2–1.4 kPa
Air temp (°F) / RH (%)
CO₂ (ppm)

POWR 4 Early Flower / Stretch

REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Early Flower / Stretch target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Early Flower / Stretch target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).
VWC (%) absolute dryback target 20–30 pp · Early Flower / Stretch
Pore EC (mS/cm) phase stack band 6.0–12.0 mS
Substrate temp (°F)
VPD (kPa) lights-on 1.0–1.2 kPa
Air temp (°F) / RH (%)
CO₂ (ppm)

Veg Room Vegetative

REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Vegetative target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).REAL 14-day hourly trace (2026-05-27 → 2026-06-10, 336 hourly room-mean points, stitched from raw ~9-min cadence). Vegetative target bands shaded. Read top-to-bottom: dryback in pp (VWC) → EC stack (pore EC) → root-zone temp → atmosphere (VPD, air/RH, CO₂).
VWC (%) absolute dryback target 5–15 pp · Vegetative
Pore EC (mS/cm) phase stack band 3.0–5.0 mS
Substrate temp (°F)
VPD (kPa) lights-on 0.8–1.1 kPa
Air temp (°F) / RH (%)
CO₂ (ppm)

Irrigation Shot-Cycle — P0 / P1 / P2 / P3Ciclo de Riego — P0 / P1 / P2 / P3

The 4-phase day is how the controller is programmed: P0 activation (lights-on → first shot — let the plant wake and start transpiring), P1 ramp-up (small shots back to field capacity + first runoff), P2 maintenance (pulses holding VWC at field capacity), P3 dry-down (last shot → next morning — the main steering lever). Shots/day, peak VWC, the field-capacity floor and overnight dryback (absolute pp) are derived from VWC step-up signatures (≥2 pp jumps in 1-h bins; no valve telemetry).El día de 4 fases: P0 activación, P1 rampa, P2 mantenimiento, P3 dry-down. Valores derivados de subidas VWC.

RoomSala PhaseFase P1 onsetinicio Shots/dayShots/día Peak VWCVWC pico FC floorPiso CC Shot targetObjetivo shot Overnight dryback (absolute pp)Dryback (pp absoluto) SteeringManejo Data agrees?¿Datos acuerdan?
POWR 1Bulkinglights-on + P0 delay1173%43%3–5%41.8 ppGenerativelyover-dry vs band
POWR 2Ripening / Flushlights-on + P0 delay454%40%6–10%31.0 ppGenerativelyagrees
POWR 3Bulkinglights-on + P0 delay1069%40%3–5%38.4 ppGenerativelyover-dry vs band
POWR 4Early Flower / Stretchlights-on + P0 delay667%52%6–10%22.3 ppGenerativelyagrees
Veg RoomVegetativelights-on + P0 delay025%25%3–5%3.8 ppVegetativelyunder-dry
Shot count / day (chip-driven) VWC step-up derived
Pore EC stack (chip-driven) substrate EC = steering output
Overnight dryback — absolute pp (chip-driven)

Phase Target RangesRangos Objetivo de Fase

Per-room phase with the AROYA target band for that phase: P1 shot size, dryback (absolute pp), pore EC band, VPD band, air-temp band and RH band. POWR 1 + POWR 4 phases are roster-verified; POWR 2/3 and the Veg Room are signal-inferred (between cycles).Fase por sala con la banda objetivo AROYA. POWR 1 y POWR 4 verificadas por roster.

Phase ladder — crop-steering targetsEscalera de fases

Root-in (dryback 10–15 pp, shot 1–3%, EC feed ~3 mS, VPD ~0.8) → Veg (dryback 5–15 pp, shot 3–5%, substrate EC 3.0–5.0, VPD 0.8–1.1) → Early flower / stretch (dryback 20–30 pp absolute, shot 6–10%, P0 delay 120–240 min, substrate EC stacking 6.0–12.0, VPD 1.0–1.2) → Bulking (dryback 12–18 pp, shot 3–5%, runoff 20–30%, substrate EC 4.0–7.0, VPD 1.2–1.4) → Ripening (dryback 25–35 pp absolute · push 40 pp final week, shot 6–10%, substrate EC 6.0–8.0, VPD 1.4–1.6). Sources: AROYA Crop Steering: The Ultimate Guide; Grodan Cannabis Edition Ch. 3–4; Athena Vegetative Stage / Substrates Guide; Growlink Crop Steering E-Book.Root-inVeg (5–15 pp) → Floración temprana (20–30 pp absoluto) → Bulking (12–18 pp) → Maduración (25–35 pp absoluto).

RoomSala PhaseFase LightsLuces P1 shot sizetamaño Dryback target (absolute pp)Dryback objetivo Pore EC bandBanda CE VPD on/offVPD on/off Temp onTemp on RH on
POWR 1
room ID 13617
Bulking (roster-verified)~12/123–5% (P1 ramp)12–18 pp absolute4.0–7.0 mS1.2–1.4 / 0.9–1.1 kPa74–80°F55–65%
POWR 2
room ID 13618
Ripening / Flush (signal-inferred)~12/126–10% (P1 ramp)25–35 pp absolute6.0–8.0 mS1.4–1.6 / 1.0–1.2 kPa72–78°F45–55%
POWR 3
room ID 13619
Bulking (signal-inferred)~12/123–5% (P1 ramp)12–18 pp absolute4.0–7.0 mS1.2–1.4 / 0.9–1.1 kPa74–80°F55–65%
POWR 4
room ID 13620
Early Flower / Stretch (roster-verified)~12/126–10% (P1 ramp)20–30 pp absolute6.0–12.0 mS1.0–1.2 / 0.8–1.0 kPa77–84°F55–65%
Veg Room
room ID 13621
Vegetative (signal-inferred)18/63–5% (P1 ramp)5–15 pp absolute3.0–5.0 mS0.8–1.1 / 0.6–0.9 kPa76–82°F60–75%

RecommendationsRecomendaciones

Prioritized, plain-language. Owner = facility lead; Grower = day-to-day room operator; Process = AROYA / Addium follow-up. Each ties to the data, the phase target and the prior commitment it closes.Priorizadas. Owner = responsable; Grower = operador; Process = AROYA / Addium.

Grower POWR 3 — run the 24 h leach (closes prior RED)
Run the overdue 24 h leach on POWR 3 zone 57895: low-EC feed (~0.5 mS) until drain EC drops below ~6 mS, then resume the normal recipe. Drain EC there still reads 11.7→14.0 mS over this window.
This was the top RED from the long-term review and it has not moved — sustained 12–15 mS drain EC with no flush is salt accumulation that caps yield and risks lockout. POWR 3 carried 34.1% of facility yield last cycle, so this room is where the leach pays back hardest.
Grower POWR 1 — deepen P3, lift VPD into the bulking band
Extend the P3 dry-down (push the last shot earlier / lengthen the overnight gap) and drop RH ~8 pp so VPD climbs from 0.89 toward 1.2–1.4 kPa. Also restore between-shot oxygenation to break the substrate-temp inversion (substrate 77.5°F ≥ air 77.5°F).
Both items carried over as YELLOW and are unchanged. Soft VPD in bulking flattens transpiration and the EC stack; the substrate-warmer-than-air inversion is an anaerobic-root risk. Same fix family: more dry-down, drier air, more air movement at the root zone.
Grower POWR 4 — lift VPD to match the EC stack (partial prior item)
POWR 4 is stacking EC well (+1.91 mS) but VPD is still 0.78 kPa vs the 1.0–1.4 target. Pull RH down / nudge temp up so the climate matches the generative push the irrigation is already driving.
The CO₂ crash is fixed and the EC trajectory is textbook — but soft VPD is the last thing holding the room back from a clean generative bulk. Aligning VPD with the EC stack is the highest-ROI tweak here.
Grower POWR 2 — hold the flush, then taper for ripening
The flush is working — substrate EC pulled back to 3.51 mS (net -0.32). Hold 7–10 more days, then taper feed for ripening rather than letting EC free-fall.
This was an INFO item and it's on track. The risk now is over-flushing into ripening; a controlled taper keeps the EC restack ripening wants (6.0–8.0 mS) reachable.
Process Add a runoff signal + confirm POWR 2/3 phases at next pull
POWR 3 already exposes drain-flow index (zones 57889/57890/57895) — surface drain EC + runoff % in the live dashboard so leaching can be graded directly instead of inferred. Re-pull the harvest-group roster once POWR 2/3 restart so their phase labels become roster-verified.
Two rooms are between cycles, so their phases are signal-inferred this run. Drain telemetry exists in POWR 3 but isn't surfaced — wiring it in turns the POWR 3 leach into a measured, closeable item next audit.

Data Quality & LimitationsCalidad de Datos y Limitaciones

This report was generated end-to-end via aroya-sdk v0.2.0. All five rooms were pulled as 7 stitched 2-day chunks each (35 sequential /rooms/<id>/chart/ GETs), deduped on timestamp, with the pull-time coverage gate (threshold 0.90) passing natively — zero 429s, zero failed chunks. Coverage below is the SDK's per-room ratio.Reporte generado de extremo a extremo con aroya-sdk v0.2.0. Cobertura por sala del SDK.

Audit-level limitationsLimitaciones
  • POWR 2 & POWR 3 phases are SIGNAL-INFERRED — both rooms are between cycles with no CURRENT harvest group, so their phase labels (ripening/flush, bulking) are read from steering signatures (EC trajectory, dryback depth in pp, photoperiod), not the AROYA calendar. POWR 1 + POWR 4 are roster-verified (Bulking/Vegetative 2).
  • Shot counts are DERIVED, not measured — a "shot" is a VWC step-up of ≥2 pp between consecutive 1-h bins. No valve-event or flow-meter telemetry exists. Counts are reliable for rhythm/consistency; absolute shot volumes (% of substrate) are not graded.
  • POWR 1's window-mean dryback (~42 pp absolute) is span-inflated — it's taken as daily VWC peak − daily VWC trough across the full day on a two-stack room, which conflates intraday swing with the true overnight peak→pre-first-shot pull. Read it as "deep-swinging", not a literal 42 pp overnight dryback. The other rooms are less affected.
  • Photoperiod inference is coarse — lights-on hours are inferred from hour-of-day CO₂/temp ramp; POWR 1/3/4 read ~12/12, Veg Room ~18/6. Good enough for DIF; not exact.
  • POWR 3 drain EC is the strongest "hot zone" signal — zone 57895 drain EC 11.7→14.0 mS (peak 14.9). Drip EC there is ~2.7 mS, so the gap is genuine in-substrate accumulation, not feed.
  • Overnight dryback (absolute pp) = daily peak VWC − the following pre-irrigation low on the zone-mean series. Per AROYA convention, never expressed relative to field capacity.
RoomSala SDK coverage ratioCobertura SDK SeriesSeries WindowVentana ChunksTramos NotesNotas
POWR 10.99914814d (336 hr-bins)7/7 okFull substrate + climate suite. Coverage gate passed natively at pull time (threshold 0.90).
POWR 20.99949714d (336 hr-bins)7/7 okFull substrate + climate suite. Coverage gate passed natively at pull time (threshold 0.90).
POWR 30.99967214d (336 hr-bins)7/7 okFull substrate + climate suite. Coverage gate passed natively at pull time (threshold 0.90).
POWR 40.99913914d (336 hr-bins)7/7 okFull substrate + climate suite. Coverage gate passed natively at pull time (threshold 0.90).
Veg Room0.99912814d (336 hr-bins)7/7 okFull substrate + climate suite. Coverage gate passed natively at pull time (threshold 0.90).