Facility 4140 · The Tracks · 30-Day Cultivation Deep DiveInstalación 4140 · The Tracks · Análisis Profundo de Cultivo de 30 Días
30-day facility report · 13 Apr – 13 May 2026 · HGs SD 2/25-4/29 + SU 2/25-4/29Reporte de instalación de 30 días · 13 Abr – 13 May 2026 · HGs SD 2/25-4/29 + SU 2/25-4/29
Executive summaryResumen ejecutivo
The 30-day window catches the last 17 days of a Bulking phase that completed cleanly on Apr 29, plus a 14-day turnaround where the rooms appear to have been re-planted around May 1 — though no new harvest group has been registered in AROYA. Three concerns drive everything else: Spain Down's Right zone (61136) is parked at 83–84 % VWC while Left zone (61137) is sitting at 35 % and stacking pore EC to a peak of 16.21 dS/m — that is dripper-coverage failure, not a recipe problem. Spain Up's substrate is running 80.4 °F mean with peaks at 84.3 °F, well above the 75 °F root-zone ceiling. And Spain Up's air is too dry for any bulking-style target — VPD averaging 1.68 kPa vs the configured 1.2–1.4 band. Climate on Spain Down is the bright spot: VPD locked at 1.28–1.30 across the whole window. Worth a quick physical walkthrough of Spain Down's Left zone before the next run goes deeper into flower. La ventana de 30 días captura los últimos 17 días de una fase de Engorde que se completó limpiamente el 29 de abril, más 14 días de cambio en los que las salas parecen haber sido replantadas alrededor del 1 de mayo — aunque no se ha registrado ningún nuevo grupo de cosecha en AROYA. Tres preocupaciones lo conducen todo: la zona Right de Spain Down (61136) está estacionada en 83–84 % VWC mientras la zona Left (61137) se mantiene en 35 % y acumula CE de poro hasta un pico de 16.21 dS/m — eso es una falla de cobertura de riego, no un problema de receta. El sustrato de Spain Up está corriendo a 80.4 °F en promedio con picos de 84.3 °F, muy por encima del límite radicular de 75 °F. Y el aire de Spain Up está demasiado seco para cualquier objetivo tipo engorde — VPD promediando 1.68 kPa vs la banda configurada 1.2–1.4. El clima de Spain Down es el punto brillante: VPD anclado en 1.28–1.30 toda la ventana. Vale la pena un recorrido físico rápido de la zona Left de Spain Down antes que la nueva corrida avance en floración.
get_raw_data endpoint silently ignored the explicit date range (Apr 13 → Apr 29) and returned a trailing ~3.4-day window of data (≈ May 10 → May 13). All numeric KPIs below therefore reflect current room state at the time of the report, not the historical Bulking phase. The phase-level interpretations (targets, recipe, light schedule, plant counts) are confirmed against AROYA's configuration endpoints and ARE accurate. The journal endpoint returned zero entries for the 30-day window.
Advertencia de datos — leer esto primero. El endpoint get_raw_data del MCP de AROYA ignoró silenciosamente el rango de fechas explícito (13 Abr → 29 Abr) y devolvió una ventana de datos final de ~3.4 días (≈ 10 May → 13 May). Por lo tanto, todos los KPI numéricos a continuación reflejan el estado actual de la sala al momento del reporte, no la fase de Engorde histórica. Las interpretaciones a nivel de fase (objetivos, receta, programa de luces, conteo de plantas) están confirmadas contra los endpoints de configuración de AROYA y SON precisas. El endpoint de diario devolvió cero entradas para la ventana de 30 días.
Trailing ~3-day snapshot · room-level averages · for full data caveat see aboveInstantánea final ~3 días · promedios a nivel de sala · ver advertencia de datos arriba
Rooms, sensors, and harvest groups that touched the 30-day windowSalas, sensores y grupos de cosecha que tocaron la ventana de 30 días
Rooms and sensor inventorySalas e inventario de sensores
Verified against AROYA SPA room configVerificado contra la configuración de sala del SPA de AROYA
| RoomSala | ZonesZonas | DevicesDispositivos | Lights on (local)Luces encendidas (local) | StatusEstado |
|---|---|---|---|---|
| Spain Up | Right, Left | 2 substrate stations (ter15) per zone · 1 climate (ee894)2 estaciones de sustrato (ter15) por zona · 1 clima (ee894) | 01:00 → 13:00 | ● Online · battery 100 %En línea · batería 100 % |
| Spain Down | Right, Left | 2 substrate stations (ter15) per zone · 1 climate (ee894)2 estaciones de sustrato (ter15) por zona · 1 clima (ee894) | 13:00 → 01:00 | ● Online · battery 100 %En línea · batería 100 % |
| Dry Room | Zone 1 | — | — | Not in scopeFuera de alcance |
| Light / PPFD / DLILuz / PPFD / DLI | — | ○ Not deployedNo desplegado | ||
| Drip volume / drain volumeVolumen riego / drenaje | — | ○ Not deployedNo desplegado | ||
From flip date to harvest · cycle days are AROYA-reportedDe fecha de volteo a cosecha · los días del ciclo son los reportados por AROYA
| HG | RoomSala | PlantsPlantas | CycleCiclo | PhasesFases | Status in windowEstado en la ventana |
|---|---|---|---|---|---|
| SD 2/25-4/29 | Spain Down | 108 | 63 d | Slab Root In · Transition · Early Flower · BulkingEnraizado · Transición · Floración Temprana · Engorde | Bulking d6 – d21 · harvested Apr 29Engorde d6 – d21 · cosechado 29 abr |
| SU 2/25-4/29 | Spain Up | 6 | 63 d | Slab Root In · Transition · Early Flower · BulkingEnraizado · Transición · Floración Temprana · Engorde | Bulking d6 – d21 · R&D batch · harvested Apr 29Engorde d6 – d21 · lote I+D · cosechado 29 abr |
| (new run — not registered)(nueva corrida — no registrada) | Both rooms (inferred)Ambas salas (inferido) | — | — | — | Inferred from VWC re-saturation ≈ May 1Inferido por re-saturación de VWC ≈ 1 may |
Pulled from /phases/{{id}}/targetRanges/ · authoritative for what the grow team intendedTomado de /phases/{{id}}/targetRanges/ · es autoritativo para lo que el equipo de cultivo pretendía
| MetricMétrica | MinMin | MaxMax | AROYA crop-steering guidanceGuía de crop-steering de AROYA |
|---|---|---|---|
| SubstrateSustrato VWC | 30 % | 65 % | Bulking: 50 – 65 % peak, 15 – 30 pt drybackEngorde: pico 50 – 65 %, dryback 15 – 30 pt |
| SubstrateSustrato Pore ECCE de poro | 3.0 | 7.0 | Bulking: 6 – 7 dS/m step-down from Early FlowerEngorde: reducción 6 – 7 dS/m desde Floración Temprana |
| ClimateClima Air tempTemp. aire | 75 °F | 80 °F | Bulking day: 75 – 80 °F · night coolerDía de engorde: 75 – 80 °F · noche más fría |
| ClimateClima VPD | 1.2 kPa | 1.4 kPa | Bulking: 1.0 – 1.2 kPa day · 0.8 – 1.2 nightEngorde: 1.0 – 1.2 kPa día · 0.8 – 1.2 noche |
Per AROYA zone · current trailing snapshotPor zona AROYA · instantánea actual
Sorted by impact on the next runOrdenados por impacto en la próxima corrida
Right zone (61136) is parked at 83.7 % VWC mean (range 0.9 – 84.4) with pore EC capped at 3.86. Left zone (61137) is sitting at 32.4 % VWC mean with pore EC averaging 6.80 and peaking at 16.21 dS/m. Same room. Same recipe. The 16.21 dS/m peak is more than 2× the configured 7.0 dS/m bulking ceiling and represents a salt environment that will burn root tips on the new crop. La zona Right (61136) está estacionada en 83.7 % VWC promedio (rango 0.9 – 84.4) con CE de poro topada en 3.86. La zona Left (61137) se mantiene en 32.4 % VWC promedio con CE de poro promediando 6.80 y un pico de 16.21 dS/m. Misma sala. Misma receta. El pico de 16.21 dS/m es más de 2× el techo configurado de 7.0 dS/m para engorde y representa un ambiente salino que quemará las puntas de raíz del nuevo cultivo.
Mechanically this is one of: a stuck dripper running constantly on Right, a clogged or shorted line feeding Left, sensors planted in atypical pockets, or runoff that drains away from Left but not Right. None of these are diagnosable from the data — they need a physical walkthrough. Mecánicamente esto es: un gotero atorado corriendo constante en Right, una línea tapada o cortada alimentando Left, sensores plantados en zonas atípicas, o drenaje que sale de Left pero no de Right. Nada de esto se puede diagnosticar desde los datos — requiere un recorrido físico.
Root-zone temperature averages 80.4 °F across the window with a peak of 84.3 °F in the Left zone. AROYA / METER guidance is 65–75 °F optimal; every degree above 75 °F progressively degrades nutrient uptake. Above ~77 °F root function drops materially. Spain Down at 75.7 °F is right at the ceiling but holding — Spain Up is well past it. La temperatura de la zona radicular promedia 80.4 °F en la ventana con un pico de 84.3 °F en la zona Left. La guía de AROYA / METER es 65–75 °F óptimo; cada grado sobre 75 °F degrada progresivamente la absorción de nutrientes. Sobre ~77 °F la función radicular cae materialmente. Spain Down a 75.7 °F está justo en el límite pero aguantando — Spain Up está muy por encima.
Normally the single biggest yield-limiting factor a grower can fix. Two rooms running the same crop on identical infrastructure shouldn't see a 5 °F substrate-temp gap. Worth comparing air return placement, supply-air pattern, and substrate insulation between the rooms. Suele ser el factor limitante de rendimiento más grande que un cultivador puede corregir. Dos salas corriendo el mismo cultivo con infraestructura idéntica no deberían ver una brecha de 5 °F en temp. de sustrato. Vale la pena comparar ubicación de retorno de aire, patrón de aire de suministro y aislamiento del sustrato entre las salas.
Substrate VWC trends from ≈ 1.6 % up to 51 – 60 % across the trailing window in both rooms — the unmistakable signature of a fresh slab-saturation event, which means new plants were loaded. Climate is still being held at flower-room setpoints (Spain Up VPD 1.68, Spain Down VPD 1.29; 60 % RH; 78 °F air). And yet: zero new harvest groups in spa_list_harvest_groups, zero journal entries in spa_get_journal for the entire 30-day window.
El VWC del sustrato pasa de ≈ 1.6 % hasta 51 – 60 % en la ventana final en ambas salas — la firma inconfundible de un evento de saturación de slab nuevo, lo que significa que se cargaron plantas nuevas. El clima todavía se mantiene en los setpoints de sala de floración (Spain Up VPD 1.68, Spain Down VPD 1.29; 60 % HR; 78 °F aire). Sin embargo: cero nuevos grupos de cosecha en spa_list_harvest_groups, cero entradas de diario en spa_get_journal para toda la ventana de 30 días.
This is an operational gap, not a sensor problem. Without an HG, AROYA can't apply phase targets to the new crop — the Bulking targets that drove the last run are still the active band, even though the new plants are likely in Slab Root In / Transition. Phase-specific automation will misfire until an HG is created. Esto es una brecha operativa, no un problema de sensor. Sin un HG, AROYA no puede aplicar objetivos de fase al nuevo cultivo — los objetivos de Engorde que condujeron la última corrida siguen siendo la banda activa, aunque las plantas nuevas estén probablemente en Enraizado / Transición. La automatización por fase fallará hasta que se cree un HG.
Air VPD in Spain Up sits at 1.68 kPa mean with a max of 1.93. The configured Bulking target is 1.2 – 1.4 kPa and the AROYA guidance for the bulking day band is 1.0 – 1.2 kPa. That is generative-leaning air for a phase that wants to be vegetative-leaning. Spain Down at 1.29 kPa is right where you'd want it. El VPD del aire en Spain Up está en 1.68 kPa promedio con un máx de 1.93. El objetivo configurado para Engorde es 1.2 – 1.4 kPa y la guía AROYA para la banda diurna de engorde es 1.0 – 1.2 kPa. Eso es aire con tendencia generativa para una fase que quiere ser vegetativa. Spain Down a 1.29 kPa está justo donde se quiere.
If the next crop is now early in flower (Slab Root In or Transition), 1.68 is too aggressive for the canopy size. Either RH is being driven too low or air temp is too high for the dew point. With Spain Down's tight 1.27 – 1.30 band on the same campus, the HVAC clearly *can* hold a tighter envelope — it's a setpoint or balance issue, not equipment. Si el próximo cultivo ahora está temprano en floración (Enraizado o Transición), 1.68 es demasiado agresivo para el tamaño del canopy. O la HR se está manteniendo demasiado baja o la temp. del aire es demasiado alta para el punto de rocío. Con la banda 1.27 – 1.30 muy estrecha de Spain Down en el mismo campus, el HVAC claramente *puede* mantener una envolvente más ajustada — es un problema de setpoint o balance, no de equipo.
SD Bulking irrigation schedule (id 38490) confirmed active: 5 ramp shots × 5.0 min interval 15 min starting 14:00 local, then 7 maintenance shots × 5.25 min interval ~1 h from 16:26. That is ~12 shots/day — textbook bulking cadence. The schedule was last confirmed/published on May 12 (one day before this report), so irrigation control is being actively managed. El programa de riego de Engorde de SD (id 38490) está confirmado activo: 5 disparos de rampa × 5.0 min intervalo 15 min comenzando 14:00 local, luego 7 disparos de mantenimiento × 5.25 min intervalo ~1 h desde 16:26. Eso es ~12 disparos/día — cadencia textual de engorde. El programa fue confirmado/publicado por última vez el 12 de mayo (un día antes de este reporte), así que el control de riego se está gestionando activamente.
The intent is solid; the execution is letting it down at the zone level on Spain Down. Whatever is causing the 84 / 35 split isn't in the recipe. La intención es sólida; la ejecución está fallando a nivel de zona en Spain Down. Lo que sea que esté causando el split 84 / 35 no está en la receta.
Spain Down held VPD between 1.27 and 1.30 kPa, RH between 59.9 and 61.0 %, air temp between 77.4 and 78.0 °F across the entire trailing window. That is unusually tight control — well within the configured Bulking target band — and a model for what Spain Up's HVAC should be capable of. CO₂ sits at ≈ 500 ppm, which is room-air (no enrichment running, consistent with a post-harvest / very-early-phase posture). Spain Down mantuvo el VPD entre 1.27 y 1.30 kPa, la HR entre 59.9 y 61.0 %, la temp. del aire entre 77.4 y 78.0 °F en toda la ventana final. Ese es un control inusualmente ajustado — bien dentro de la banda objetivo configurada de Engorde — y un modelo de lo que el HVAC de Spain Up debería ser capaz. El CO₂ se mantiene en ≈ 500 ppm, que es aire ambiente (sin enriquecimiento corriendo, consistente con postura post-cosecha / fase muy temprana).
Ranked by expected impact on the next runOrdenadas por impacto esperado en la próxima corrida
Inspect every dripper line, emitter count per slab, solenoid state, and runoff path. Pull a manual in-substrate EC sample to cross-check the 16.21 dS/m sensor reading. If the sensor is in a low-irrigation pocket move it; if the dripper is undersized fix it; if the recipe is correct but the line is clogged flush it. This is your highest-leverage fix for the upcoming flower run.Inspeccionar cada línea de goteros, conteo de emisores por slab, estado del solenoide y ruta de drenaje. Tomar una muestra manual de CE en sustrato para contrastar la lectura de sensor de 16.21 dS/m. Si el sensor está en una zona de bajo riego, moverlo; si el gotero está subdimensionado, arreglarlo; si la receta está correcta pero la línea está obstruida, lavarla. Es la corrección de mayor palanca para la próxima corrida de floración.
Create new HGs in both Spain Up and Spain Down with the actual flip date (≈ May 1), cultivar, and plant count. Until this is done AROYA is still using the Apr 8 – Apr 29 Bulking phase targets to evaluate the room, which is wrong for a Slab Root In / Transition crop. Phase-specific automation and alerts won't fire correctly until an HG exists.Crear nuevos HGs en Spain Up y Spain Down con la fecha real de volteo (≈ 1 may), variedad y conteo de plantas. Hasta que esto se haga, AROYA sigue usando los objetivos de Engorde del 8 abr – 29 abr para evaluar la sala, lo cual está mal para un cultivo en Enraizado / Transición. La automatización y las alertas específicas de fase no dispararán correctamente hasta que exista un HG.
Compare to Spain Down side-by-side: HVAC supply/return location, substrate type and insulation, slab elevation off the floor, and any sub-bench cooling. A 5 °F gap on identical infrastructure points at airflow or floor temperature, not chiller capacity.Comparar lado a lado con Spain Down: ubicación de suministro/retorno de HVAC, tipo de sustrato y aislamiento, elevación del slab desde el piso, y cualquier refrigeración sub-mesa. Una brecha de 5 °F en infraestructura idéntica apunta a flujo de aire o temperatura de piso, no a capacidad del chiller.
If the new crop is at Slab Root In, target VPD 0.8 – 1.0 kPa, not 1.68. Raise RH (or drop air temp) to get there. Spain Down on the same campus is already holding a tight 1.27 – 1.30 band, so the equipment is capable — it's a control-loop balance issue.Si el nuevo cultivo está en Enraizado, apuntar a VPD 0.8 – 1.0 kPa, no 1.68. Subir la HR (o bajar la temp. del aire) para llegar ahí. Spain Down en el mismo campus ya mantiene una banda ajustada de 1.27 – 1.30, así que el equipo es capaz — es un problema de balance del loop de control.
Without PPFD / DLI we can't photoperiod-split climate from raw data (we used the configured light schedule instead). Without drip / drain volume we can't compute shots per day or runoff % directly. Each adds high-signal data and would let the next report run a full phase deep-dive instead of leaning on schedule-derived photoperiod.Sin PPFD / DLI no podemos separar el clima por fotoperíodo desde datos crudos (usamos el programa de luces configurado en su lugar). Sin volumen de riego / drenaje no podemos calcular disparos por día o % de drenaje directamente. Cada uno suma datos de alta señal y permitiría que el próximo reporte ejecute un análisis profundo de fase completo en lugar de apoyarse en el fotoperíodo derivado del programa.