AROYA by Addium · Device Health · TopLine Grow (facility 4620) · 2026-06-12

TopLine Grow · Device Health

Full 10-device fleet, grouped by room. Status window: 48h sweep, audit window 2026-05-29 → 2026-06-12. Source: local verified cache — no live pull in this render.

How to read this: the 48h sweep for this fleet returned no per-device battery / RSSI / link / travel series (stats columns honestly show “—”); status is graded on last device communication + room data flow, which is unambiguous here. Nodes and their TEROS One heads are battery-powered; the gateway and sink are PoE — never put mesh infrastructure on a battery or USB charger. The gateway and sink do not emit a device-level series through this endpoint — a known API behaviour, not an offline device; their health is proven by Room 2 delivering 100% of its substrate data all window. Node serials (H-prefix) are shown in full; sensor-head serials are masked as “head on <node serial>” per convention.
Fleet size
10
Room 1 devices silent
4 / 4
Room 2 devices reporting
4 / 4
Zones with no devices
2
The P0 finding: Room 1 has been dark for 8 days. All four Room 1 devices (2 battery Nodes + their 2 TEROS One substrate heads, zone Table 1-3) stopped communicating at 2026-06-04 13:00 UTC. Room 2 ran at 100% coverage the entire window, so the gateway, sink and mesh backhaul are healthy — the outage is local to Room 1's devices. The cultivation data before the stop reads as end-of-cycle (final dry-down, then probes in-air), so the most likely story is the Nodes were powered down or pulled at harvest teardown — or their batteries are spent. Action before re-plant: re-seat the probes in new media, power the Nodes, replace batteries if needed, and confirm fresh readings in the AROYA app before the first irrigation of the next cycle. If a new run starts while these are dark, it starts blind.

Fleet inventory

ModelCountPlaced in a roomInfrastructure / unplaced
Node (battery, mesh)440
TEROS One substrate head (on Node)440
Sink (PoE)101
Gateway (PoE)101

Room 1 — 4 devices (zone Table 1-3) ALL SILENT

2× Node (battery) + 2× TEROS One substrate head. Zone Table 4-6 has no devices — half the room is unsensed even when these come back.

SerialModelZonePowerStatus (48h)RSSIBatteryLast seen (UTC)
H3440011048nodeTable 1-3batterysilent — last comm 2026-06-04 13:00 UTC (8 days)2026-06-04 13:00
H3440011048-2nodeTable 1-3batterysilent — last comm 2026-06-04 13:00 UTC (8 days)2026-06-04 13:00
head on H3440011048-2ter15Table 1-3batterysilent — last comm 2026-06-04 13:00 UTC (8 days)2026-06-04 13:00
head on H3440011048ter15Table 1-3batterysilent — last comm 2026-06-04 13:00 UTC (8 days)2026-06-04 13:00

Room 2 — 4 devices (zone Table4-6) ALL REPORTING

2× Node (battery) + 2× TEROS One substrate head, last comm 2026-06-12 12:57 UTC. Zone Table 1-3 has no devices — the room's dryback story is read from one of its two table groups.

SerialModelZonePowerStatus (48h)RSSIBatteryLast seen (UTC)
H3440011049nodeTable4-6batteryreporting2026-06-12 12:57
H3440011049-2nodeTable4-6batteryreporting2026-06-12 12:57
head on H3440011049-2ter15Table4-6batteryreporting2026-06-12 12:57
head on H3440011049ter15Table4-6batteryreporting2026-06-12 12:57

Facility infrastructure — 2 devices

Gateway + sink (PoE, not room-assigned — normal). No device-series via the API (known artifact); proven healthy by Room 2's uninterrupted data flow.

SerialModelZonePowerStatus (48h)RSSIBatteryLast seen (UTC)
H2110001311gatewayPoEno device-series via API (PoE — not offline; backhaul proven by Room 2 data flow)
SINKH2110001311sinkPoEno device-series via API (PoE — not offline; backhaul proven by Room 2 data flow)

Telemetry timeline — when each room's substrate data stopped/continued

Days of substrate telemetry delivered per room (of 14-day audit window)
Coverage gaps and recommendations: (1) Bring Room 1's 4 devices back online before re-plant — P0. (2) No climate devices exist at this site (no Atmos 14 / Climate One / CO₂) — the audit could not grade VPD, RH risk or the P0 irrigation delay; one PoE climate sensor per room closes that gap. (3) Two zones (Room 1 Table 4-6, Room 2 Table 1-3) have no devices at all — add or relocate a Node + TEROS One pair at turnover so both table groups per room are sensed.

Source: local cache aroya-cache/facility-4620/2026-06-12 (config/devices.json + device_health.json 48h sweep + room readings). Battery models: Node + TEROS One head. Gateway / sink are PoE. Contact: cian@addium.com · Cian Sullivan · Addium / AROYA