2-room cultivation audit · Wood Wide: Jane Lane (facility 2858) · 2026-06-12 → 2026-06-26 — REAL 14-day hourly trace stitched from AROYA public_api (2-day windows, ~9-min native cadence). No active harvest group is recorded in AROYA for these rooms this window, so phases are signal-inferred from photoperiod, dryback depth, EC trajectory and VPD — worth confirming the current crop is being tracked in a harvest group. Room mix: 2× Bulking. Facility-wide the sensed rooms average 11.1 pp overnight dryback, pore EC 5.13 mS, lights-on VPD 1.36 kPa. 2 items flagged below. Top flags: Flower 1 RH 69.1% is high for bulking (target 55–65%); Flower 2 dryback 8.8 pp is below the bulking band (12–18 pp).2-room cultivation audit · Wood Wide: Jane Lane (facility 2858) · 2026-06-12 → 2026-06-26 — REAL 14-day hourly trace stitched from AROYA public_api (2-day windows, ~9-min native cadence). No active harvest group is recorded in AROYA for these rooms this window, so phases are signal-inferred from photoperiod, dryback depth, EC trajectory and VPD — worth confirming the current crop is being tracked in a harvest group. Room mix: 2× Bulking. Facility-wide the sensed rooms average 11.1 pp overnight dryback, pore EC 5.13 mS, lights-on VPD 1.36 kPa. 2 items flagged below. Top flags: Flower 1 RH 69.1% is high for bulking (target 55–65%); Flower 2 dryback 8.8 pp is below the bulking band (12–18 pp).
This audit grades each room's live steering signatures against the AROYA phase target bands (dryback in absolute pp, substrate EC stack, VPD and climate). Phases are signal-inferred this run; the per-room cards below state steering intent before the numbers and pair every observed value with the band for that phase.Esta auditoría compara cada sala con las bandas objetivo AROYA. Fases inferidas por señal.
Per-room VPD window, lights-on vs lights-off air-temp swing (DIF), humidity vs the phase target, and CO₂ dose.Por sala: VPD, DIF, HR y CO₂.
| Room | Phase | VPD on | VPD off | Temp on | Temp off | DIF | RH on | CO₂ on | Flag | Verdict |
|---|---|---|---|---|---|---|---|---|---|---|
| Flower 1 | Bulking | 1.12 | 1.10 | 83.4 | 78.5 | 4.9 | 71.2 | n/a | RH high vs band | RH/VPD off |
| Flower 2 | Bulking | 1.59 | 1.62 | 76.7 | 74.6 | 2.2 | 48.5 | 573 | high-VPD | RH/VPD off |
Does the VPD profile match the shot rhythm and the EC stack? Higher-VPD days pull water faster and need P2 maintenance; calmer days allow a deeper P3 dry-down.¿El VPD coincide con el ritmo de riego?
| Room | Phase | Peak VPD | VWC envelope | Pore EC | Overnight dryback (absolute pp)Dryback (pp absoluto) | VPD on |
|---|---|---|---|---|---|---|
| Flower 1 | Bulking | 1.36 | 21.6–39.8% | 5.49 mS stacking | 13.4 pp in band | 1.11 |
| Flower 2 | Bulking | 2.33 | 6.0–37.4% | 4.77 mS stacking | 8.8 pp below | 1.61 |
One card per room. Steering intent stated before the numbers. Dryback in absolute percentage points (peak VWC − pre-irrigation low). Substrate EC read as the result of steering.Una tarjeta por sala. Dryback en pp absolutos.
Per room: VWC, pore EC, substrate temp, VPD, air-temp / RH, CO₂ over 14 days with phase bands shaded.Por sala: VWC, CE, temp, VPD, aire/HR, CO₂.
The 4-phase day: P0 activation, P1 ramp to field capacity, P2 maintenance pulses, P3 overnight dry-down (the main steering lever). Observed P1 onset, shots/day, P2 pulses, peak VWC and overnight dryback — derived from VWC step-up signatures (≥0.8 pp between ~9-min samples; no flow telemetry).Día de 4 fases. Valores derivados de subidas VWC.
| Room | Phase | P1 onset | Shots/day | P2/day | Peak VWC | Shot target | Overnight dryback (absolute pp)Dryback (pp absoluto) | Steering | Agrees? |
|---|---|---|---|---|---|---|---|---|---|
| Flower 1 | Bulking | 08:48 ± 0.4h | 4.0 | 0.0 | 39% | 3–5% | 13.4 pp ± 1.8 | Vegetative | agrees |
| Flower 2 | Bulking | 09:13 ± 0.4h | 2.1 | 0.0 | 25% | 3–5% | 8.8 pp ± 8.0 | Vegetative | under-dry |
Per-room phase (signal-inferred) with the AROYA target band: P1 shot size, dryback (absolute pp), pore EC, VPD, air-temp and RH.Fase por sala con banda objetivo AROYA.
| Room | Phase | Lights | P1 shot | Dryback (abs pp) | Pore EC | VPD on/off | Temp on | RH on |
|---|---|---|---|---|---|---|---|---|
| Flower 1 SOILLESS · 4 zone · room ID 6534 | Bulking (signal-inferred) | ~12h photoperiod | 3–5% (P1 ramp) | 12–18 pp absolute | 4.0–7.0 mS | 1.2–1.4 / 0.9–1.1 kPa | 74–80°F | 55–65% |
| Flower 2 SOILLESS · 4 zone · room ID 6535 | Bulking (signal-inferred) | ~11h photoperiod | 3–5% (P1 ramp) | 12–18 pp absolute | 4.0–7.0 mS | 1.2–1.4 / 0.9–1.1 kPa | 74–80°F | 55–65% |
Prioritized from the data. Owner = facility lead; Grower = room operator; Process = AROYA / Addium follow-up.Priorizadas. Owner / Grower / Process.
Coverage = % of expected hourly samples over the 14-day window.Cobertura = % de muestras horarias.
| Room | VWC cov | EC cov | Climate cov | Window | Notes |
|---|---|---|---|---|---|
| Flower 1 | 100% | 100% | 100% | 14d | Full substrate + climate suite. |
| Flower 2 | 100% | 100% | 100% | 14d | Full substrate + climate suite. |